7.4.1

Control panel overview

7
eco
6
5
Fig. 29 Control panel
[1]
Display
 and  keys: To navigate through menus and increase/decrease
[2]
settings
[3]
d key: Return/back
[4]
ok key: Save settings, Chimney sweeper key (Service Engineer
function): press 5 seconds for chimney sweeper mode
[5]
eco key: Hot water preheat selection
[6]
Hot water key: Adjusting the hot water temperature
[7]
Heating key: Heating mode on, set the maximum flow
temperature
7.4.2

Turn on the appliance

Set the language the first time the appliance is turned on.
▶ To scroll through the languages, press the  or the  key.
▶ To select the desired language, press the ok key.
When the symbol
appears alternately with the flow temperature,
the siphon filling program is active. The condensate siphon in the
appliance is filled ( chapter 7.4.3).
Detailed operating settings
Appliance operation
▶ Refer to Operating Instructions for full details on setting the CH flow
temperature, DHW temperature set point and the operating settings
menu information.
Condens 8300i W – 6721841533 (2022/12)
1
reset
ok
5 sec
3
4
0010021505-001
WARNING
Risk of scalding!
This appliance may deliver water at high temperature.
▶ Refer to the plumbing code of Australia (PCA), local requirements
and installation instructions to determine if additional delivery
temperature control is required.
▶ This appliance is supplied with the CH control set at approximately
65 °C, a temperature that should be suitable for most installations
that comply with current Building Regulations. When the boiler
switches from CH to DHW, the temperature of the hot water may
2
briefly exceed the DHW set point if the CH temperature is set higher
than the DHW temperature. If the CH temperature is changed to
above 65 °C, it is advisable to fit a thermostatic mixing valve (TMV) at
the point of use (e.g. before the bath hot tap or shower) to protect
vulnerable people from scalding.
7.4.3

Siphon filling mode, manual activation/de-activation

The siphon filling mode is activated automatically or manually by the
installer on the appliance.
▶ Press the (key and the * key simultaneously, until L.A will be
displayed.
▶ Press the key repeatedly, until L.4 will be displayed.
▶ Press the ok key to confirm.
▶ Select and adjust service function 4-A2.
The siphon filling mode is activated automatically in the following cases:
• The appliance is switched on using the fuse spur.
• The burner was not in use for at least 28 days.
• After switching from summer to winter mode.
• After a reset.
The next time there is a heat requirement for heating, the appliance is
held at low thermal output for 15 minutes. The siphon filling mode
remains active until the appliance has completed 15 minutes of
operation with increased min. capacity.
During the siphon filling program, the symbol
with the flow temperature on the display.
The siphon filling mode is interrupted when the chimney sweep mode is
started.
7.5

Chimney sweep mode

You have 15 minutes to take your measurements or to make your
settings. After this time the appliance returns to normal operation. When
running in the chimney sweep mode, the appliance will operate both the
central heating and the domestic hot water circuits. This is to allow
sufficient time for this part of the commissioning procedure. It will be
necessary to run water through the domestic hot water circuit to ensure
that the appliance will not overheat whilst in chimney sweep mode.
In chimney sweep mode the rated output of the appliance can be
selected.
▶ Press the ok key until the countdown is completed and the symbol
appears.
▶ Set the desired rated output min and max using the  or the  keys.
The value is accepted after 2 seconds.
▶ To exit the chimney sweep mode, press the d key.
Adjustment with casing removed in chimney sweep mode
1. Set the chimney sweep mode and start up the appliance at maximum
rated output.
2. Set the chimney sweep mode and set the appliance at minimum rated
output.
Commissioning
appears alternately
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc8300iw 25 pGc8300iw 35 p

Table of Contents