Note: Don't use CO10RF coordinator with UGE600 simultaneously!
RX10RF (optional)
Additional, wireless device control module that can be used - for example - when we can't use cable between the KL08RF wiring centre and the boiler.
The KL08RF wireless wiring centre is a part of the iT600RF system. In combination with the wireless thermostats from iT600RF series, KL08RF provides comfortable and reliable heating control. It is equipped with the control outputs for the pump and boiler and has been designed to work with NC or NO actuators.
In Offline mode, communication with the wireless thermostats from iT600RF series must be done through the CO10RF co-ordinating unit, which is in the package together with the wiring centre. To work in Online mode (via the SALUS Smart Home app) KL08RF must be connected to the Internet gateway UGE600. In one ZigBee network (Online or Offline) up to 9 KL08RF wiring centres can be connected. KL08RF increases ZigBee network range.
This product complies with the essential requirements and other relevant provisions of Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Power Supply | 230 V AC 50 Hz |
Max load | 3 A |
Inputs | CO terminal Dew point sensor (humidistat) |
Outputs | Pump control Boiler control Terminals for actuators |
Radio frequency | ZigBee 2,4 GHz |
Dimensions [mm] | 355x83x67 |
Note: Fuse replacement should be done when the wiring centre is disconnected from power supply 230 V AC.
The mains fuse is located under the housing cover, at the main terminals and protects the wiring centre and devices powered by it. Use cartridge fuse-type 5 x 20 mm - nominal burn rate 12 A. To remove the fuse, lift the socket with a flat screwdriver and pull out the fuse.
Power supply for wiring centre is 230V ~, 50Hz.
Features of the installation:
This function is only available in Offline mode (together with CO10RF coordinator) - it means MASTER thermostats will affect to SLAVE thermostats within specific group, which is possible only when thermostats are paired with one KL08RF wiring centre (optional + KL04RF) and have been assigned to gr. 1 or gr. 2.
Note: Within one group there may be only one MASTER thermostat (programmable) and the rest must be SLAVE thermostats (non-programmable).
How it works: If all thermostats of a given group will operate in automatic mode, then each of the thermostats in a given group will work in the same way as the MASTER of this group. For example, if the MASTER thermostat of Group 1 according to it's programmed schedule maintains a comfort mode - all SLAVE type thermostats from Group 1 will also maintain the comfort mode (the temperature is set individually for every thermostat). Similarly, if the MASTER thermostat is set to Party or Holiday mode - SLAVE thermostats in his group will also work in these modes.
The grouping function is optional - thermostats do not have to be grouped, they can operate independently.
LED diode statuses:
(LED diode is blinking) - it means wiring centre is not connected to the network, but it is ready for pairing with the coordinator (CO10RF) of the ZigBee network or the Internet gateway (UGE600) | |
(LED is steady lit) - it means wiring centre is added to the ZigBee network and paired with CO10RF or UGE600 |
Functions of the Pair button:
Boiler off delay time.
Note: Pump (Pump output) and boiler (Boiler output) always starts 3 minutes after receiving the heating signal from any thermostats paired with wiring centre. Pump stops after 3 minutes, when the last thermostat stops sending demand for heat, while the heat source (Boiler) will turn off after the time set with the jumper.
Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
There is an option to connect the 08RFA external antenna to the wiring centre. If you use an additional antenna, place the jumper in the EXT position.
Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
Select the type of the thermoelectric actuator connected to the wiring centre:
NC – actuator normally closed
NO – actuator normally opened
Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
The ZigBee network coordination unit CO10RF is used for Offline mode and it's included with the wiring centre. CO10RF enables wireless control of all devices installed in one network. Within one network can be connected max 9 wiring centres. It means that if in the network there are more than one wiring centre, you can use one coordinator and put the remaining ones in a safe place.
Note: Do not use CO10RF coordinator with UGE600 simultaneously.
Wires of the thermoelectric actuators should be plugged into the self-locking connectors in the appropriate zones. You can connect 3 actuators directly to one zone. The current load of one zone is adapted to operate with up to 6 thermoelectric actuators with a power of 2 Watts. If there is a need to connect more than 6 actuators please use an additional relay to relieve the output of the zone.
Note: On the actuator contacts, there is voltage 230 V AC during their work.
Pump output - this is a volt free output (COM / NO) that controls the circulation pump in the heating / cooling system. The output closes (pump starts) always after 3 minutes after receiving the heating / cooling signal from any of thermostats paired with wiring centre. The output opens (pump stops) after 3 minutes, when the last thermostat stops sending heat / cold demand.
Boiler output - this is a volt free output (COM / NO) that controls the boiler in the heating system. The output closes and the boiler turns on but always after 3 minutes after receiving the heating signal from any of thermostats paired with wiring centre. The output opens and the boiler switches off when the last thermostat stops sending heat demand (after the time set on the Delay jumper).
Boiler output is inactive in the cooling mode.
Opened CO input contacts (Changeover) means that whole system works in the heating mode. Short circuit at the input CO will automatically switch the whole system to cooling mode (wiring centre and paired thermostats).
CO terminal | Diode | Mode |
Opened contacts | Red | Heating |
Closed contacts | Blue | Cooling |
Dew point sensor input is active only in cooling mode (with closed CO contacts).
Shorting the contacts at the dew point sensor input (too high humidity) causes switching off all zones in the wiring centre and Pump control outputs.
It is used for communication between the KL08RF wiring centre and the KL04RF extension module. KL04RF extension module increases functionality and expands support up to 12 zones.
The external antenna connector 08RFA is located underneath the wiring centre under zones 7 and 8. After connecting an additional antenna, place the jumper in the EXT position.
Jumper position change must be refreshed in the memory by pressing the Reset button (short press).
To identify the wiring centre in the ZigBee network, follow the steps below:
In Online mode (using the SALUS Smart Home app):
In Offline mode:
To restore the factory settings, press and hold the Pair button for 15 seconds. G1 and G2 diodes will turn red and go out.
Note: If you restore the factory settings of the wiring centre, all paired devices will be removed from the ZigBee network - you will have to synchronize them again.
Head Office: SALUS Controls plc
SALUS House Dodworth Business Park South,
Whinby Road, Dodworth, Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961 E: sales@salus-tech.com
www.salus-controls.com
SALUS Controls is a member of the Computime Group. Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Salus Controls KL08RF - ZigBee Network Wireless Wiring Centre Manual