5.2 - FUNCTIONING
Connect pump to the system.
Ensure that valve is in the closed position.
-Fill the tank with water.
-Add cleaning chemical to the tank.
- Switch on the pump and clean the system.
The YAK-01 has 1 x 250 cm Pressure Line and 1 x 250 cm Return Line hoses fitted with
3/4" brass hose connectors at the out board end and 3/4" fittings at the inboard end.
In cleaning process:
The inboard end of "Pressure Line Hose" should be screwed onto the corresponding ¾"
brass nipples on rear of the hose support plate. The other end of this hose should be connected
to the system inlet (radiator/boiler/pump).
The inboard end of "Return Line Hose" should be screwed onto the corresponding ¾" brass
nipples on rear of the hose support plate. The other end of this hose should be connected to
the system outlet (radiator/boiler/pump).
In dumping process:
Disconnect the Return Line hose screwed on rear of the hose support plate and lead it to a toilet
pan or drain pipe gully leading to a foul sewer.
5.3 - HOW TO CLEAN THE PUMP
After descaling REMOVE THE DESCALING LIQUID FROM THE TANK and wash out the pump by
circulating clean water through it for at least 10 minutes.

6 - SAFETY INSTRUCTIONS

- Avoid using the pump in rooms where there are liquids, gases, flammable powders or with risk of
explosion.
- Before plugging in the pump to the outlet, make sure the switch is off.
- The outlet must be suitable for the plug of the pump. Do not use non CE-marked defective outlets.
- Use (CE) approved extensions, only if necessary.
- Do not use plug adapter. Do not carry out any modifications to the plug nor to the electrical cable.
- Pump shall always kept in perfect efficiency.
- During maintenance operations, check the switch is off and the plug is not connected.
- All maintenance operations must be carried out by the authorized Technical Assistance Service.
- Only use KAMMAKoriginal spare parts.
- Do not carry out any modifications to the pump if not authorized by Technical
Department (ask for written authorization).
- Keep children and unauthorized persons away from the pump.
- Keep the pump out of reach of children and unauthorized persons.
- Do not use the pump if tired or under the effect of alcohol, medicines or drugs.
- When using the pump, wear overalls, do not wear jewellery, keep hair away from the pump.
- When handling descaling liquids, be very careful. It is necessary to use Individual Protection
Equipment (IPE).
Never run the pump without water!