5. Setting and Adjustment

Before turning on the power, check the setting shown in this section.
5.1

MAIN Module - T9NC1

5.1.1

Battery Connector - CNBT1

The battery for memory back-up is in the main module T9NC1. The battery should
be connected CNBT1 on the main module.
5.1.2

DIP Switch - SW4

The dip switch SW4 is used for PLC system. You can operate it from the outside of
the case.
No.
Name
1
INITIAL
2
3
LINE END
4
RUN / STOP Sequence program RUN / STOP
Table 5.1.1
Functions
Off: Normal
On: Sequence memory is initialized when the power is turned
on.
Reserved
Terminator circuit for communication line of distributed I/O
Normally, it should be ON.
On: Terminator circuit is ON. (Normal)
Off: Terminator circuit is OFF.
On; Sequence program RUNs.
Off: Sequence program STOPs.