9.7 5 1/4-Inch Disk Drive

9-26
If the auto-loader is installed in a previously unused drive bay, assign the
next available SCSI address to the auto-loader (from 0 to 6, depending on
the system configuration). For example:
Your system has both a CD-ROM drive and a
bottom right bay, ID6 and ID 5. If all other drive bays are empty, you can:
Install the tape drive in any of the other three drive bays.
Assign the next available SCSI address, ID 4 in this example, to the newly
installed auto-loader (regardless of which bay is used).
12. Use the device select switch to set the SCSI address for the installed auto-
loader.
Press the buttons marked "+" or "-" until you reach the proper address.
The differential SCSI disk tray can contain up to six disk drives. See
Figure 9-32. The first drive in the tray should be installed in the Drive I
location, the second in the Drive II location, and so on.
Front of tray
Fans
Drive V
Drive III Drive IV
Drive I

Figure 9-32 Drive Locations in Drive Tray