I
ntroductIon
Reasonable care and safe methods should be
practiced. Check local codes and requirements
before installation. This manual contains important
information for the safe use of this product. Read
this manual completely before using this product and
refer to it often for continued safe product use.
DO NOT THROW AWAY OR LOSE THIS MANUAL.
Keep it in a safe place so that you may refer to it when
needed.
I
S
mportant
afety
Before proceeding further, kindly go through the
safety instructions carefully.
Always disconnect the unit from the receptacle power
source and battery before handling or making any
adjustments to the system.
2
3
6
4
7
I
nStrutIonS
OPERATION MANUAL
Dated: 07/23/2013
Document Name: 30ACi_OM
Battery Backup Warning:
WARNING: Risk of electrical shock this unit
has not been investigated for use in outdoor
areas.
WARNING: Risk of electrical shock. Connect
only to a properly grounded, three pronged
grounding type receptacle. Under any circumstances,
do not remove the grounding prong from the power
cord.
WARNING: Do not smoke, use spark able
electrical devices or open flame when working
on this unit!
WARNING: Do not install unit in locations
classified as hazardous per N.E.C., ANSI/
NFPA 70 - 1999.
FAILURE TO HEED ABOVE CAUTIONS COULD
RESULT IN INJURY OR DEATH.
WARNING: The 30ACi system is designed to
operate only one pump, the one supplied
with the unit. Using anything other than the pump
supplied with the system will cause damage to the
unit and void the warranty.
General Precautions:
Before using the inverter, read all instructions and
caution markings on the inverter, the batteries & all
appropriate sections of this instruction manual.
WARNING: Do not expose the inverter to any
type of chemicals. The inverter is designed
for interior use only.
WARNING: Do not disassemble the inverter;
take it to a qualified service center when
service or repair is required. Opening by unqualified
personnel can lead to electrical shock or fire hazard
and void the warranty.
To reduce risk of electric shock, disconnect all wiring
before cleaning.
WARNING: Avoid exposing the inverter or
batteries to any type of explosive gases (in
the vicinity, as batteries generate explosive gases
Register your product at www.sumpro.com
Page 1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for ION 30ACi

  • Page 1 5. Ion Pipe-Mount Bracket, PN: IN-PUMPBKT-1 ® 6. Pig Tail with Anderson Connector WARNING: The 30ACi system is designed to 7. Power Cord operate only one pump, the one supplied with the unit. Using anything other than the pump ntroductIon supplied with the system will cause damage to the unit and void the warranty.
  • Page 2: Battery Safety

    30ACi OPERATION MANUAL Dated: 07/23/2013 Battery Back-Up System Document Name: 30ACi_OM Page 2 of 12 during normal operation). Provide proper ventilation. attery afety The battery enclosures should be designed to prevent accumulation and concentration by hydrogen gas in A battery can present a risk of severe burn and “pockets”...
  • Page 3: Battery Maintenance

    30ACi OPERATION MANUAL Dated: 07/23/2013 Battery Back-Up System Document Name: 30ACi_OM Page 3 of 12 When Inverter is Operating on DC Power alkaline and maintenance free. Batteries are sealed or vented. 1. Follow Steps 1 – 4 above. Starting Batteries 2.
  • Page 4: Tools Needed

    4. Lay wires on over the short side of the battery an inverter, battery box, pig tail with Anderson box so the Anderson connector is on the outside connector, inverter power cord and pump with Ion ® of the battery box. Install the plastic cover on switch.
  • Page 5 30ACi OPERATION MANUAL Dated: 07/23/2013 Battery Back-Up System Document Name: 30ACi_OM Page 5 of 12 and the pump cord into the switch cord. See from top to bottom. The battery percentage will Page 5, Figure A. slowly start to drop. The inverter is now in DC mode, taking the battery power and using it 8.
  • Page 6 30ACi OPERATION MANUAL Dated: 07/23/2013 Battery Back-Up System Document Name: 30ACi_OM Page 6 of 12 30ac anel The inverter has two battery leads coming out from the back of the inverter, with a grey Anderson connector on the end, a MCB (main circuit breaker), pump output socket (120 volt) and a power cord to connect with AC power (120 volt).
  • Page 7: C Omponent P Art N Umbers

    Pump cord is not making contact in openings. receptacle. ii. Pump impeller may be partially clogged d. Ion switch may not be working properly. with tar or paint, causing motor to run slow and overload. Remove pump and i. Plug pump directly into wall outlet clean.
  • Page 8 Inlet holes in pump base may be clogged. a. Unplug the pump/Ion plug from the inverter. Remove pump and clean the openings. b. Plug the pump back into the Ion plug and b. Pump impeller may partially clogged with plug the Ion plug into a wall outlet.
  • Page 9 If the pump does not turn on, the switch may have to be replaced. 15. Any tags or labels have been removed from the inverter, pump or Ion Digital Level Control ™ iv. If the pump does turn on, continue to switch.
  • Page 10 30ACi OPERATION MANUAL Dated: 07/23/2013 Battery Back-Up System Document Name: 30ACi_OM Page 10 of 12 oteS Register your product at www.sumpro.com...
  • Page 11 30ACi OPERATION MANUAL Dated: 07/23/2013 Battery Back-Up System Document Name: 30ACi_OM Page 11 of 12 3 Year Residential Warranty Coverage and Term. Metropolitan Industries, Inc. (“Metropolitan”) warrants to the original purchaser (the “Buyer”) of each StormPro/Sumpro product (the “product”), that any part thereof which proves to be defective in material or workmanship within three (3) years from date of manufacture, will be replaced at no charge with a new or remanufactured part, F.O.B.