(4) Outdoor fan control
(a) Outdoor fan tap and fan motor speed
Model
FDC100
Note If the "silent mode start" signal is received from the remote control and SW7-3 is ON, the speed changes from 600 to 500.
(b) Fan tap control during Cooling/Defumidifying operation
Fan taps are selected depending on the outdoor heat exchanger temperature (Tho-R1, R2) and the outdoor air temperature (Tho-A).
Note It is detected by Tho-R1 or R2, whichever the higher.
zone
zone
Tap 5
zone
Tap 5
zone
Tap 4
zone
Tap 3
zone
zone
15
18
Outdoor air temperature (˚C)
(c) Fan tap control during heating operation
Fan taps are selected depending on the outdoor heat exchanger temperature (Tho-R1, R2) and the outdoor air temperature (Tho-A).
Note It is detected by Tho-R1 or R2, whichever the lower.
zone
zone
Tap 3
zone
Tap 3
zone
Tap 4
zone
zone
zone
3
9
Outdoor air temperature (˚C)
(d) Outdoor fan control at cooling low outdoor air temperature
(i) If the outdoor air temperature (Tho-A) is in the zone
with ±5 – ±30min
Note It is detected by Tho-R1 or R2, whichever the higher.
zone
20
Outdoor air temperature (˚C)
Mode
➀ speed ➁ speed ➂ speed ➃ speed ➄ speed ➅ speed ➆ speed
Cooling/Dehumidifying
Heating
zone
zone
Tap 5
Tap 5
Tap 5
Tap 4
(1)
Tap 4
Tap 3
(1)
Tap 3
Tap 2
zone
zone
46
48
30
37
zone
zone
Tap 3
Tap 4
Tap 4
Tap 5
(1)
Tap 5
Tap 6
zone
zone
zone
12
15
12
15
3
9
Outdoor air temperature (˚C)
-1
to keep high pressure level which is controlled by outdoor heat exchanger temperature (Tho-R1, R2).
zone
200
350
600
(1)
200
350
600
(1)
Note If the "silent mode start" signal is received from the remote control,
zone
the speed changes from Tap 4 to Tap 3.
Tap 4
Tap 3
Tap 2
Tap 1
zone
zone
20
30
Outdoor heat exchanger temperature (˚C)
Note
If the "silent mode start" signal is received from the remote control, the speed
changes from Tap 4 to Tap 3.
zone
zone
1
zone
zone
-2
0
-2
0
Outdoor heat exchanger temperature (˚C)
Outdoor heat exchanger temperature (˚C)
in the cooling/dehumidifying mode, outdoor fan is controlled
154
-
-
'22 • PAC-SM-422
Fan motor tap
740
820
870
740
820
870
zone
zone
43
53
33
40
zone
zone
3
1
3
Unit: min
-1
950
950