14 Inspection and maintenance
The equipment is subject to pressure!
▶ Risk of severe injury or death.
Depressurize the plant.
●
Completely drain the plant.
●
Hot plant components!
▶ Risk of burns.
Only work on plant that has cooled
●
down.
Servicing and maintenance work must only be performed
●
by trained personnel.
GEMÜ shall assume no liability whatsoever for damages
●
caused by improper handling or third-party actions.
In case of doubt, contact GEMÜ prior to commissioning.
●
Exceptional maintenance work!
▶ Damage to the GEMÜ product.
Any maintenance work and repairs not described in these
●
operating instructions must not be performed without
consulting the manufacturer first.
The operator must carry out regular visual examination of the
GEMÜ products dependent on the operating conditions and
the potential danger in order to prevent leakage and damage.
The product also must be disassembled and checked for
wear in the corresponding intervals.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in plant op-
erator's guidelines.
3. Shut off plant or plant component.
4. Secure the plant or plant component against recommis-
sioning.
5. Depressurize the plant or plant component.
6. Actuate GEMÜ products which are always in the same po-
sition four times a year.
www.gemu-group.com
WARNING
CAUTION
CAUTION
NOTICE
14.1 Spare parts
14.1.1 Spare parts MG 25, MG 40, MG 50
20
19
19
18
Item
A
Actuator
2
Diaphragm
1
Body
18,19, 20
Mounting set
14.1.2 Spare parts MG 80
20
19
19
18
Item
A
Actuator
2
Diaphragm
1
Body
18,19, 20
Mounting set
14.2 Cleaning the product
The pulsation damper can be cleaned (CIP) and sterilized
(SIP) without being removed. The conditions in the "Technical
data" chapter (operating, cleaning and sterilization media,
temperatures) must be complied with.
21 / 26
14 Inspection and maintenance
A
2
1
Name
Order designation
9652
600 M
K652
652 S30
A
2
1
Name
Order designation
9652
600 M
K652
652 S30