Physical Specifications; Environmental Specifications; Ordering Information - Nortel Passport 8608GTE Specifications

Ethernet routing switch 8600 release 5.1
Hide thumbs Also See for Passport 8608GTE:
Table of Contents

Advertisement

• RFC 1450 Management Information Base for v2 of the Simple
Network Management Protocol (SNMPv2)
• RFC 1472 The Definitions of Managed Objects for the Security
Protocols of the Point-to-Point Protocol
• RFC 1483 Multiprotocol Encapsulation over ATM Adaptation
Layer 5
• RFC 1493 Bridge MIB
• RFC 1525 Definitions of Managed Objects for Source Routing
Bridges
• RFC 1565 Network Services Monitoring MIB
• RFC 1573 Interface MIB
• RFC 1643 Ethernet MIB
• RFC 1650 Definitions of Managed Objects for the Ethernet-like
Interface Types using SMIv2
• RFC 1657 BGP-4 MIB using SMIv2
• RFC 1658 Definitions of Managed Objects for Character Stream
Devices using SMIv2.)
• RFC 1695 Definitions of Managed Objects for ATM Management
v8.0 using SMIv2
• RFC 1696 Modem Management Information Base (MIB) using
SMIv2
• RFC 1724 RIP v2 MIB Extension
• RFC 1850 OSPF MIB
• RFC 2021 RMON MIB using SMIv2
• RFC 2037 Entity MIB using SMIv2
• RFC 2096 IP Forwarding Table MIB
• RFC 2233 Interfaces Group MIB using SMIv2
• RFC 2452 IPv6 MIB: TCP MIB
• RFC 2454 IPv6 MIB: UDP MIB
• RFC 2465 IPv6 MIB: IPv6 General group and textual conventions
• RFC 2466 IPv6 MIB: ICMPv6 Group
• RFC 2578 Structure of Management Information v2 (SMIv2)
• RFC 2613 Remote Network Monitoring MIB Extensions for
Switched Networks v1.0
• RFC 2665 Definitions of Managed Objects for the Ethernet-like
Interface Types
• RFC 2668 Definitions of Managed Objects for IEEE 802.3
Medium Attachment Units (MAUs)
• RFC 2674 Bridges with Traffic MIB
• RFC 2787 Definitions of Managed Objects for the Virtual Router
Redundancy Protocol
• RFC 2863 Interface Group MIB
• RFC 2925 Remote Ping, Traceroute & Lookup Operations MIB
• RFC 2932 IPv4 Multicast Routing MIB
• RFC 2933 IGMP MIB
• RFC 2934 PIM MIB

Ordering information

Chassis, power supply and software
Order code
Description
DS1402001
8010 10 slot chassis. Includes chassis, dual backplane, two fan trays, RS232 cable for management console, rack mount kit and cable guide kit. Requires
at least one power supply, up to three power supplies supported.
DS1402002
8006 6 slot chassis. Includes chassis, dual backplane, fan tray, RS232 cable for management console, rack mount kit and cable guide kit. Requires at
least one power supply, up to three power supplies supported.
DS1402004
8010co 10 slot NEBS chassis. Includes chassis, fan trays, RS232 cable for management console, rack mount kit and cable management. Requires at least
two 8004 or 8005 power supplies, up to three power supplies supported. Supports 8600 modules only.
DS1405012-ES
8005AC 100-240 VAC 1140W/1462W Power Supply. At least one power supply required per 8006, 8010 or 8010co chassis. Lower output at 110VAC.
Cannot mix with 8004 series supplies. Power cord ordered separately-use AA00200xx series cords.
DS1405011
8005DC 1462W Power Supply. At least one power supply required per 8006, 8010 or 8010co chassis. Cannot mix with 8004 series supplies.
DS1410003-5.0
ERS 8600 Routing Switch Base Software Kit (Includes v5.0 base SW license, Device Manager, and complete SW documentation set).
One license kit required per chassis. (Support contracts must be purchased separately.)
DS1410005-6.2
Enterprise Switch Manager version 6.2
DS1405018-E6
Ethernet Routing Switch 8005 Dual Input AC Power Supply
DS1411018-E6
8006CM HS – Cooling Module High Speed – Fan Tray for 8006. Required for RS-Modules. One per chassis.
DS1411017-E6
8006CM HS – 8010CM HS – Cooling Module High Speed – Fan Tray for 8010. Required for RS-Modules. Two per chassis.
Switch fabrics and RS Modules
Order code
Description
DS1404065
Ethernet Routing Switch 8692SF Switch Fabric/CPU to enable redundant terabit core configurations. One required with R Modules, second for load-
sharing and redundancy. Operable with pre-E, E and M modules. Includes 256MB SDRAM and 64MB PCMCIA.
DS1404066
8692SF Switch Fabric/CPU with factory-installed Enterprise Enhanced CPU Daughter Card (SuperMezz). SuperMezz is a mandatory requirement for IPv6,
Sub-100msec failover, MPLS, IP VPN-Lite, IP VPN and VRF-Lite. Both 8692SF must have the SuperMezz installed; no mixed configurations.
DS1411025
Enhanced CPU Daughter Card (SuperMezz) for 8692SF. Includes dual 1Ghz processors. SuperMezz is a mandatory requirement for IPv6,
Sub-100msec failover, MPLS, IP VPN-Lite, IP VPN and VRF-Lite. Both 8692SF must have the SuperMezz installed; no mixed configurations.
DS1404097-E6
8612XLRS - 12 port 10GBase-X LAN XFP Routing Switch Module baseboard (XFPs sold separately). Requires the use of the 8692SF.
DS1404102-E6
8648GBRS - 48 port SFP Routing Switch Module baseboard (SFPs sold separately). Requires the use of the 8692SF.
DS1404109-E6
8634XGRS Combo 2 port 10GBase-X XFP, 24 port SFP (with 100FX support) and 8 port auto sensing 10/100/1000TX Routing Switch
Module baseboard (XFPs and SFPs sold separately). Requires the use of the 8692SF.
DS1404110-E6
8648GTRS - 48 port auto sensing 10/100/1000TX Routing Switch Module baseboard. Requires the use of the 8692SF.
• RFC 3019 IPv6 MIB: MLD Protocol
• RFC 3411 An Architecture for Describing Simple Network
Management Protocol (SNMP) Management Frameworks
• RFC 3412 Message Processing and Dispatching for the Simple
Network Management Protocol (SNMP)
• RFC 3416 v2 of the Protocol Operations for the Simple Network
Management Protocol (SNMP)
• RFC 3635 Definitions of Managed Objects for the Ethernet-like
Interface Types
• RFC 3636 Definitions of Managed Objects for IEEE 802.3 Medium
Attachment Units (MAUs)
• RFC 3810 Multicast Listener Discovery v2 (MLDv2) for IPv6
• RFC 3811 Definitions of Textual Conventions (TCs) for
Multiprotocol Label Switching (MPLS) Management
• RFC 3812 Multiprotocol Label Switching (MPLS) Traffic
Engineering (TE) Management Information Base (MIB)
• RFC 3813 Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB)
• RFC 3815 Definitions of Managed Objects for the Multiprotocol
Label Switching (MPLS), Label Distribution Protocol (LDP)
• RFC 4022 Management Information Base for the Transmission
Control Protocol (TCP)
• 4087 IP Tunnel MIB
• RFC 4113 Management Information Base for the User Datagram
Protocol (UDP)
• RFC 4624 Multicast Source Discovery Protocol (MSDP) MIB

Physical specifications

Ethernet Routing Switch 8006
• Height: 15.8 in. (40.1 cm)
• Width: 17.5 in. (44.5 cm)
• Depth: 19.9 in. (50.5 cm)
• Weight (empty): 49 lb (22 kg)
• Weight (fully loaded): 140 lb (63 kg)
• Cooling system:
– Fan trays: 1 per chassis
– Fans: 20 per fan tray
– Thermal sensors: 1 per fan tray
Ethernet Routing Switch 8010
• Height: 22.9 in. (58.2 cm)
• Width: 17.5 in. (44.5 cm)
• Depth: 19.9 in. (50.5 cm)
• Weight (empty): 85 lb (39 kg)
• Weight (fully loaded): 225 lb (102 kg)
• Cooling system:
– Fan trays: 2 per chassis
– Fans: 15 per fan tray
– Thermal sensors: 1 per fan tray
Safety agency approvals
• UL Listed (UL1950)
• IEC 950/EN60950
• C22.2 No. 950 (CUL) with all national d eviations
• UL-94-V1 Flammability requirements for
PC board
• NOM (NOM-019)

Environmental specifications

• Operating temperature: 0°C to 40°C
(32°F to 104°F)
• Storage temperature: -25°C to 70°C
(-13°F to 158°F)
• Operating humidity: 85% maximum r elative humidity,
noncondensing
• Storage humidity: 95% maximum relative humidity,
noncondensing
• Operating altitude: 3024 m (10,000 ft) maximum
• Storage altitude: 3024 m (10,000 ft) maximum
• Free fall/drop: ISO 4180-s, NSTA 1A
• Vibration: IEC 68-2-6/34
• Shock/bump: IEC 68-2-27-29
Electromagnetic emissions
summary
Meets the following standards:
• US: CFR47, Part 15 Subpart B, Class A
• Australia/New Zealand: NZS 3548:1995, Class A
• Canada: ICES-003, Issue 2, Class A
• Japan: V-3/97.04:1997, Class A
• Taiwan: CNS 13438, Class A
• EN 55022:1995, Class A
• EN 61000-3-2:1995
• EN 61000-3-3:1994
• Electromagnetic immunity: Meets the EN 50082-1:1997
standard
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Passport 8608sxeErs 8006Ers 8010

Table of Contents