3-1 LED Lighting Message

Message
Input Power Plug
Standby
Power button ON
Lamp retry
Power off
(Cooling state)
Power button OFF:
Cooling completed;
Standby Mode
Error (Thermal
Failure)
Error (Fan lock)
Error (Lamp break-
down)
Error (Color Wheel
Failure)
Note: Steady Light: "V"
No Light: "--"
Red
Flash ON to OFF 100ms
V
--
--
0.5 second H(ON),
0.5 second L(OFF) flashing
V
0.5 second H(On), 0.5 second L(Off) flashing red twice, and blue
LED ON 2 second, and by returns
0.5 second H(On), 0.5 second L(Off) flashing red twice, and blue
LED ON 2 second, and by returns
0.5 second H(On), 0.5 second L(Off) flashing blue twice, and red
LED ON 2 second, and by returns
0.5 second H(On), 0.5 second L(Off) flashing blue twice, and red
LED ON 2 second, and by returns
Power LED
0.5 second H(On),
0.5 second L(Off) flashing
X1161/X1261
Confidential
Blue
--
--
V
--
--
3-1