8.5. Condensed Water Drainage
This air conditioner employs a "Slinger-Up System" which is designed to splash the condensed
water on the condenser coil for maximum cooling efficiency, thus producing a splashing
sound. If the splashing sound annoys you, you can provide an outside drainage by using the
following procedure which may, however, cause a small loss of performance.
Note:
If the unit is installed at coastal area, drainage of condensed water is recommended to prevent
the condenser being corroded easily.
1. Remove the rubber plug and slide the chassis out from the
cabinet.
2. Install the drain pan.
Install the drain pan at the right corner of the cabinet using 2
screws.
3. Connect a drain hose. Fit the drain hose to the drain pan.