2. Remove the brushes from the tool by
pulling on the spring that is attached to the
carbon brush. If the brush is less than 1/8"
long and the end surface of the brush that
contacts the commutator is rough and/or
pitted, they should be replaced. Check
both brushes (Fig. 11).
Usually the brushes will not wear out simul -
taneously. If one brush is worn out, replace
both brushes. Make sure the brushes are
installed as illus trated. The curved surface of
the brush must match the curvature of the
commutator. Also check that the brush caps
sit flush with the tool housing.
3. After replacing brushes the tool should be
run at no-load; place it on a clean surface
and run it freely at full speed for 5 minutes
before loading (or using) the tool. This will
allow the brushes to "seat" properly and
will give you more hours of life from each
set of brushes. This will also extend the
total life of your tool since the com mutator
BEARINGS
surface will "wear" longer.
Model 4300 has ball bearing construction.
Under normal use no additional lubrication is
Cleaning
required.
To
avoid
always dis connect the
tool from the power supply before
cleaning or performing any main tenance.
Certain cleaning agents
and solvents damage
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlo rinated cleaning
solvents,
ammonia
and
detergents that contain ammonia.
Ventilation openings and switch levers must
If an extension cord is
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
NOTE: The smaller the gauge number, the
receptacles.
higher the cord capacity.
18
GlobalTestSupply
www.
accidents
be kept clean and free of foreign matter. Do
not at tempt to clean by inserting pointed
household
objects through openings.

Extension Cords

RECOMMENDED SIZES OF ExTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
50
3-6
18
16
6-8
18
16
8-10
18
16
10-12
16
16
12-16
14
12
FIG. 10
BRUSH CAP
FIG. 11
BRUSH SPRING
Curved end of brush
must match curvature of
commutator
BRUSH
Wire Sizes in mm 2
Cord Length in Meters
15
30
60
120
100
150
16
14
0.75
0.75
1.5
2.5
14
12
0.75
1.0
2.5
4.0
14
12
0.75
1.0
2.5
4.0
14
12
1.0
2.5
4.0
.com