Mitsubishi Electric FREQROL HC Instruction Manual page 84

Transistorized inverter
Table of Contents

Advertisement

Name (Type)
Dirt-protection
• By installing this option in the slits at the top,
structure attachment
bottom, right and left of the high power factor
FR-ACV
converter, the high power factor converter can be
changed to be an enclosed structure model (IP40).
(The box-shaped attachment is added to the wiring
section of 11K to 22K.)
• Adequate for wall mounting application, etc.IP40
(JEM1030): Structure which prevents a wire,
copper band or the like in excess of 1mm in
diameter or thickness from entering into the high
power factor converter.
Note 1: This structure is not protected from water and
Note 2: When
Conduit connection
• Used to connect a conduit pipe directly to the
attachment
bottom of the high power factor converter.
• By installing this attachment, 11K to 55K (200V,
FR-AFN
400V) are changed in structure specification to
IP20. (IP00 is standard.)
Note: Secured by a total of four places, the two
Radio noise filter
FR-BIF
200V class
FR-BIF-H
400V class
fluid entry and is therefore not appropriate for
environments often exposed to water drops
or oily smoke.
this
attachment
permissible ambient temperature of the high
power factor converter is -10°C to +40°C.
High power factor converter
FR-AFN
*
P
P
(Installation panel surface)
installation screws at the bottom of the high
power factor converter and the two places at
the bottom of the FR-AFN.
White
Red Blue
Green
29
29
58
Specifications, Structure, Etc.
Type
FR-ACV01
FR-ACV02
FR-ACV03 FR-HC-7.5K
FR-ACV04 FR-HC-15K
FR-ACV05
is
used,
the
Type
FR-AFN01
.
FR-AFN02
FR-AFN03
FR-AFN04
FR-AFN05 FR-HC-7.5K
FR-AFN06 FR-HC-15K
FR-AFN07
FR-AFN08 FR-HC-30K
FR-AFN09
FR-AFN10 FR-HC-55K
(Note)
Attachment Outline Drawing (Unit: mm)
Type
FR-AFN01
2-φR hole
FR-AFN02
FR-AFN03
FR-AFN04
FR-AFN05
FR-AFN06
FR-AFN07
N-φD hole
FR-AFN08
FR-AFN09
(with rubber bush)
FR-AFN10
* Same dimensions as those of the high power factor converter.
(Unit: mm)
Leakage current:4mA
Power
supply
φ5 hole
Note: 1. This filter must not be connected to the
7
44
- 71 -
Applicable High Power Factor Converter
200V class
400V class
FR-HC-H7.5K
FR-HC-H15K
Applicable High Power Factor Converter
200V class
400V class
FR-HC-H7.5K
FR-HC-H15K
FR-HC-H30K
FR-HC-H55K
L
H
P
N
D
45
56
48
2
35
45
71
48
2
35
45
75
48
3
35
45
115
48
3
35
55
115
60
3
44
70
115
68
3
50
145
115
68
4
50
145
95
68
4
50
285
120
113
3
91
285
120
113
4
91
Reactor 1
NFB
FR-BIF
output circuit of the high power factor
converter.
2.The cables should be as short as
possible and connected to the terminal
block of the high power factor converter.
M
R
60
6
60
6
60
6
60
6
70
6
90
10
185
10
102.5
10
227.5
12
227.5
12
R
S
T

Advertisement

Table of Contents
loading

Table of Contents