Wiring Of The Control Circuit - Mitsubishi Electric FREQROL HC Instruction Manual

Transistorized inverter
Table of Contents

Advertisement

1.3.4 Wiring of the control circuit

(For terminal block functions, refer to "Terminals" on page 58.)
Output signals
Alarm output
(1 change-over contact output)
Open collector
outputs
Control input signals (voltage input disabled)
Note: 1.Terminals SD and SE are common to the I/O signals and are isolated from each other. Do not
earth (ground).
2.Use shielded or twisted cables for connection to the control circuit terminals and run them
away from the main and power circuits (including the 200V relay sequence circuit).
3.Since the control circuit input signals are micro currents, use two parallel micro signal contacts
or a twin contact to prevent a contact fault.
4.Keep the free terminals (NC) unconnected. Otherwise, the high
power factor converter may become faulty.
5.When connecting two crimping terminals to one of the control
circuit terminals, round or square open-ended crimping terminals
of the size as shown on the rightshould be used back to back.
Do not use the free terminals (NC) of the control circuit. Using them will lead to the
failure of the high power factor converter and inverter.
Steep distortion or sinking in power may cause the reactor 2 (FR-HCL02) to generate
unusual noise. This phenomenon occurs due to a power fault and is not attributable to
a damaged high power factor converter (FR-HC).
When the load is light, harmonic suppression effects will decrease.
Be sure to connect terminal RDY of the FR-HC to the X10 or MRS signal assigned
terminal of the inverter, and connect terminal SE of the FR-HC to terminal SD of the
inverter. Without proper connecting, FR-HC will be damaged.
Open collector
output common
Multi-purpose
output terminal
Multi-purpose
output terminal
Overload alarm
Converter reset
Converter operating
Inverter operation
enable
Meter connection
common
Meter connection
Contact input common
Monitor switching
Monitor switching
Converter stop
Reset
External transistor common
(Note)
A
B
C
High
(NC)
power
factor
(NC)
converter
(NC)
(NC)
Note: A voltage applied in the wrong
(NC)
(NC)
(NC)
SE
Y2
Y1
OL
RSO
CVO
RDY
SD
(NC)
FM
(NC)
SD
(NC)
X2
(NC)
X1
(NC)
SOF
(NC)
RES
(NC)
PC
CAUTION
- 26 -
RDY
CVO
RA
RSO
OL
V1
Y2
SE
direction will damage the high
power factor converter. Beware
of
miswiring
such
direction of diode connection.
F
F
Nominal B(mm)
F(mm)
1.25-3
6.4 or less
53 or more
Note: Round crimping terminal V1.25-MS3
(Japan Solderless Terminal)
Power
supply
24V or
12VDC
as
the

Advertisement

Table of Contents
loading