10
To Light the SECOND BURNER
■ After the first burner exhibits a proper flame, turn the first flame adjuster to
"LOW" (Fig. 29).
■ Turn the second flame adjuster back and forth several times to clean generator
tip (Fig. 30).
FIG. 29
■ Turn flame adjuster to "High/Light" (Fig. 31).
■ Hold lighted match at second burner and then open the second fuel
valve (Fig. 32).
■ CAUTION: If stove burns with a high yellow flame or if liquid fuel appears in the
burner, immediately turn FUEL VALVE "OFF." Allow stove to cool. Carefully
review the troubleshooting section before relighting stove.
■ After 60 seconds, pump an additional 40 strokes. Flame may be adjusted to
desired heat with FLAME ADJUSTER. Turn flame adjuster back and forth
several times to clean generator tip (Fig. 30).
■ Pump as required to maintain flame height.
FIG. 31
English-11
FIG. 30
FIG. 32