Operation
continued.
Lighting Instructions for HEATER
3. Pilot Light will ignite and be
visible through Pilot Viewing Port
(flame may be difficult to see in
broad daylight). Continue to push
Heater Control Knob in for 30 to
60 seconds after pilot is on, then
release knob. Pilot Light must
remain on, if not return to
step 1.
Pilot
Pilot
Viewing
Port
Port
Note: If pilot fails to remain lighted, all valves should be closed and a
waiting period of at least 5 minutes should pass before attempting to
light.
4. Rotate Heater Control Knob to ON position. Heater burner will light and
be visible through screen of heater. If Main burner does not light, turn off
Heater Control Knob and return to Step 1.
Heater
Control
Knob
Lighting Instructions for LIGHT
1. Push in and rotate Light Control Knob to the ON position while pushing
the Igniter Button until BOTH mantles are lighted.
Note: If BOTH mantles are not lighted within 5 seconds, turn Light
Control Knob to OFF position. All controls should be turned to the OFF
position and a period of at least 5 minutes should pass before
reattempting to light burners.
2. Mantles will light and begin to
glow which can be seen through
the windows. If the mantles do not
light or fail to remain lighted turn
OFF Light Control Knob and return
to Step 1.
Unit can be operated with
heater & light both operating or
either operating separately.
continued.
Igniter
Light
Control
Knob
Igniter
Match Lighting Instructions for HEATER
1. Turn cylinder valve on.
3. Use a long match. Locate Pilot Port directly above center glass panel.
4. Light a long fireplace match (minimum 4" long) and insert into Pilot
Port, then push in and hold Heater Control Knob.
5. Pilot light will ignite and be visible from Pilot Port or Pilot Viewing Port.
Continue to push Heater Control Knob in for 30 to 60 seconds after
pilot is on, then release knob. Pilot light must remain on, if not return to
Step 1.
Note: If pilot fails to remain lighted, all valves should be closed and
a waiting period of at least 5 minutes should pass before attempting
to light.
6. Rotate Heater Control Knob to ON position. Heater burner will light
and be visible through screen of heater. If Heater burner does not light,
turn off Heater Control Knob and return to Step 1.
2. Push in and rotate (counter
clockwise) Heater Control Knob
to the Pilot position and release.
Pilot
Port