Repair instruction
Test procedure:
The test procedure allows you to check the basic functions of the appliance.
1. Test step 1: Enter the test procedure:
a. Keep the 2-cup button pressed while connecting the appliance to the mains.
b. The button can be released when the 1-cup, 2-cup and jug LED are switched on.
Heater and pump should be off .
2. Test step 2: 1-cup button, 1-cup LED and heater
a. Press the 1-cup button and hold it.
b. 1-cup LED and heater turn on. Other LEDs and the pump are off . Heater is on for a maximum of 3 seconds or if
1-cup button is released.
c. Release the 1-cup button.
d. Heater turns off , 1-cup LED remain on.
3. Test step 3: 2-cup button, 2-cup LED and pump
a. Press the 2-cup button and hold it.
b. 2-cup LED and pump turn on. Other LEDs and the heater are off .
c. Release the 2-cup button.
d. Pump turns off , 2-cup LED remain on.
4. Test-step 4: Test temperature sensor and descale LED
a. Press the 1-cup button and hold it.
b. The descale LED turns on. Other LEDs and the heater are off .
c. If the temperature sensor is connected and has the right value (approx. 1.5 kOhm) the pump turns on.
d. Disconnect the temperature sensor and the pump turns off .
e. Release the 1-cup button, CALC LED remain on.
5. Test-step 5: Test water level sensor
a. Press the 2-cup button and hold it.
b. The 2-cup LED turns on. Other LEDs and the heater are off .
c. Hold a magnet for the water level sensor and the pump turns on.
d. Remove the magnet and the pump turns off .
e. Release the 2-cup button.
6. To proceed to the fi nal test step shortly push the 1-cup button.
(Pump starts shortly, 1-cup and CALC LED remain on)
7. Test-step 7: Test Jug button
a. Press the jug button and hold it.
b. All LEDs and the heater are off .
c. The pump turns on after ± 300 ms.
d. Release the jug cup button.
e. Descale LED and jug button LED turn on and the pump turns off .
8. End of test procedure.
Unplug appliance from the mains to exit test procedure.