A.O. Smith TE-35 User Manual page 11

Tankless electric water heater
Table of Contents

Advertisement

Electrical connection to the Water Heater should have circuit breaker, do not use any
adapters. Use multimeter to check whether the live line and neutral line are not reverse, to
ensure complete safety.
meter capacity and electric supply cable of 2.5 sq. mm is used.
The Water Heater should be earthed reliably. It is prohibited to connect the earth wire to
neutral wire or faucet water pipe.
If the power supply cord is damaged, it must be replaced by the manufacturer or Authorised
Service Technician in order to avoid a hazard.
In order to avoid a hazard due to inadvertent re-setting of the Thermal cut-out, this Water
Heater must not be supplied through an external switching device, such as a timer, or
connected to a circuit that is regularly switched ON and OFF by the utility.
Figure 13
Service
cover
LED
display
Power
touch
button
1. Switch ON the Water Heater's power supply and Power touch button in the water heater. The
LED display glows as shown.
2. Turn ON/OFF the cold water inlet supply for the heater to start/stop heating.
3. Press the "+" or "-" touch button until the required temperature is displayed on the LED display.
changed as set temperature and stored in memory. It will return to its normal mode and
the heating of the water is based on the new set temperature. Temperature setting range is
between 30°C to 55°C.
4. Check hot water with hand before you taking a shower.
CAUTION
CAUTION
Temperature setting
touch button
9