Replacing the charcoal filter (only
KMDA 7272 FR-U, KMDA 7272 FL-U)
The charcoal filter must be replaced
after 120 operating hours. The 
sensor control will light up.
The designation of the charcoal filter
can be found in the "Optional accessor-
ies" section.
 Remove the cover grille.
 Remove the grease filter.
 Remove the charcoal filter.
Cleaning and care
Cleaning the vapour extraction
drip tray
Clean the drip tray if liquid from food
being spilled or boiling over has got into
the vapour extraction unit.
 Remove and clean the grease filter as
described in "Cleaning and care –
Grease filter/Cover grille".
 Push the plastic bracket to the left 
until the drip tray can be pulled
downwards .
 Pour out the liquid.
 Clean and dry the drip tray.
 Also clean and dry accessible areas
inside of the vapour extraction unit.
 Fasten the drip tray back onto the
casing.
 Replace the grease filter and refit the
cover grille.