Compact type
Mounting procedure
1. Fit the fixing claw (bottom side) from the top side or bottom side of the switch
body along the root of the cable.
<When installing on the top side>
2.
<When installing on the top side>
2
Removal procedure
The procedure for removing the maintenance actuator from the compact type is the
same as that for removing the maintenance actuator from the visible type.
6
OUTPUT OPERATION AND INDICATOR OPERATION
When this product is installed on the switch body, the switch body outputs and the
indicators operate as follows. This enables a distinction from an abnormal door open
state.
Their operations for the collective maintenance type (SG-PK-M1
those for the individual maintenance type (SG-PK-M2).
The operations of the switch body outputs and the indicators for each maintenance
actuator are as described below.
WARNING
If the maintenance actuator is not used correctly, it will cause an accident.
When using the maintenance actuator, understand its operations well and
use it correctly.
When using the collective maintenance type
Switch body (Standard)
Indicator
<Example: When connecting 3 units>
Standard unit
OSSD1
ON
OSSD2
Maintenance
OFF
actuator
(Maintenance)
OSSD1 only turns ON
Note: When using the collective maintenance type, the individual maintenance type (SG-PK-M2) cannot be used.
Standard
Type
Detection
Actuator
Indicator Actuator
state
Detected
Yellow
Detected
Yellow
Collective
mainte-
Detected
Yellow
nance
Mainte-
Normal
nance
Not
Red
detected
After
Blinking
12 hours
Detected
in yellow
(Note 1)
/ red
Notes: 1) The maintenance actuator is valid for the maximum of 12 hours consecutively. After 12 hours, the OSSD1
turns OFF and the switch body indicator blinks (in yellow / red). When using the maintenance actuator again,
install it again.
SG-P Series Instruction Manual.
When using the individual maintenance type
Switch body (Standard or sub)
Indicator
<When installing on the bottom side>
1
<When installing on the bottom side>
2
Maintenance Actuator
SG-PK-M1
Sub unit 1
Sub unit 2
Normal actuator
Normal actuator
(Normal)
Sub unit 1
Sub unit 2
Detection
Detection
Indicator Actuator
Indicator
state
state
Detected
Yellow
Detected
Yellow
Not
Detected
Yellow
Red
detected
Not
Red
Detected
Yellow
detected
Normal
Blinking
Blinking
Detected
Detected
in green
in green
Blinking
Blinking
Detected
in yellow
Detected
in yellow
/ red
/ red
Maintenance Actuator
SG-PK-M2
<Example: When connecting 3 units with the maintenance actuator installed on the sub unit 1>
OSSD1
OFF
OSSD2
ON
OSSD2 only turns ON
Type
Actuator
Individual
1
mainte-
nance
Normal
After
12 hours
(Note)
Note: The maintenance actuator is valid for the maximum of 12 hours consecutively. After 12 hours, the OSSD2 turns
OFF and the switch body indicator blinks (in yellow / red). When using the maintenance actuator again, install it
again.
7
SPECIFICATIONS
Type
Model No.
Ambient temperature
Ambient humidity
Vibration resistance
Shock resistance
Material
Weight
8
DIMENSIONS
21
10.7
1.8
8
(Normal)
OSSD1 OSSD2
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
PRINTED IN JAPAN
Standard
Sub unit 1
Maintenance
Normal actuator
actuator
(Normal)
(Maintenance)
Standard
Sub unit 1
Detection
Detection
Indicator Actuator
Indicator Actuator
state
state
Detected
Yellow
Detected
Yellow
Blinking
Not
Red
Detected
in yellow
detected
/ red
Mainte-
Blinking
Not
nance
Detected
Red
in green
detected
Blinking
Blinking
Detected
in yellow
Detected
in yellow
/ red
/ red
Collective maintenance type
SG-PK-M1
0 to +40ºC (No condensation)
(storage: -25 to +65ºC)
35 to 85% RH
(storage: 35 to 85% RH)
Double amplitude: 1 mm
2 hours each in X, Y, and Z directions
Durability: 300 m/s
3 times each in X, Y, and Z directions
POM (polyacetal)
7 g
39.5
8
10
1.5
2
3.2
© Panasonic Industrial Devices SUNX Co., Ltd. 2021
Sub unit 2
Normal actuator
(Normal)
Sub unit 2
OSSD1 OSSD2
Detection
Indicator
state
Detected
Yellow
OFF
ON
Blinking
Detected
in yellow
OFF
OFF
/ red
Normal
Blinking
Detected
OFF
OFF
in green
Blinking
Detected
in yellow
OFF
OFF
/ red
Individual maintenance type
SG-PK-M2
2
(approx. 30 g)
Unit : mm
23
102
93
97.8

Advertisement