LG DL 385 Series Owner's Manual page 28

Table of Contents

Advertisement

Available languages

Available languages

28 INSTALLATION
3
Press the Start/Pause button.
• The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
4
Check the display for results.
• During the test cycle, monitor the Flow
TM
Sense
display on the control panel. If the
TM
Flow Sense
LED has not turned on when
the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense
on. Other problems may also be shown with
error codes. See the chart on the next page
for error code details and solutions.
• If the Flow Sense
exhaust system is severely restricted, have
the system checked immediately, as
performance will be poor.
• During the test cycle, monitor the Flow
TM
Sense
display on the control panel. If no
bars are displayed, when the cycle ends, the
exhaust system is adequate. If the exhaust
system is severely restricted, the display will
show four bars. Other problems may also
be shown with error codes. See the chart on
the next page for error code details and
solutions. If four bars indicates that the
exhaust system is severely restricted, have
the system checked immediately, as
performance will be poor. (DL*360**)
TM
LED will turn
TM
LED indicates that the
5
End of cycle.
• At the end of the test cycle,
display. The test cycle will end and the
appliance will shut off automatically after a
short delay.
Check the Duct Condition
TM
If the Flow Sense
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
• When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the results during the
two tests may not be the same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the LED doesn't light up during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Dryer section of this manual for complete
exhaust system and venting requirements.
Error Codes
Check the error code before you call for service.
Error
Possible Cause & Solution
Code
Temperature sensor failure.
or
tE1
tEz
• Turn off the appliance and call for
service.
Humidity sensor failure.
Hs
• Turn off the appliance and call for
service.
Electric dryer power cord is not
,
,
Ps
PF
connected correctly, or house power
or
NP
supply is incorrect.
• Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
• If the problem is a circuit overload,
have it corrected by a qualified
electrician.
or
will
ENd