7.1 Arming Follows Partition

(default = disabled) A partition can be set to follow the arming and
disarming status of one or more partitions.
Section:
Partition 1: [3121]
Partition 2: [3221]
Partition 3: [3321]
Partition 4: [3421]
Partition 5: [3521]
Partition 6: [3621]
Partition 7: [3721]
Partition 8: [3821]

7.2 Trouble Latch

S
[3033]: O
[6]
ECTION
PTION
With the Trouble Latch feature disabled, when a trouble occurs and is
corrected, the trouble is automatically cleared and no longer displayed.
With the Trouble Latch feature enabled, the trouble will remain displayed
until it is manually cleared by the user. To clear the trouble, the user must
enter the trouble display and then exit the trouble display. For LCD and
LED keypads, press [
] to exit. For Grafica keypads, press the left
CLEAR
action key (Back) to exit.
Only troubles that have been corrected can be cleared. If a
trouble has not been corrected, it will continue to be displayed
even if the user tries to clear the trouble by using the method
described above.

7.3 Restrict Arming on Supervision Loss

S
[3034]: O
[4]
ECTION
PTION
(default = disabled) When enabled, arming is restricted if a supervision
loss signal from the Magellan Wireless System MG-RTX3 is received.

7.4 Restrict Arming on Tamper

S
[3034]: O
[8]
ECTION
PTION
(default = disabled) When enabled, the control panel prevents arming if it
detects a tamper on a zone or module (see section 8.5 on page 19).
Partitions will not arm until the Installer Code is entered and the tamper
trouble conditions are corrected.

7.5 Restrict Arming on AC Failure

S
[3035]: O
[1]
ECTION
PTION
(default = disabled) When enabled, the control panel prevent arming if it
detects a loss of AC power.

7.6 Restrict Arming on Battery Failure

S
[3035]: O
[2]
ECTION
PTION
(default = disabled) When enabled, the control panel prevents arming if it
detects a battery loss or if the battery voltage is less than 10.5V.

7.7 Restrict Arming on Bell or Auxiliary Failure

S
[3035]: O
[3]
ECTION
PTION
(default = disabled) When enabled, the control panel prevents arming if:
• the bell or siren is disconnected
• the Bell Output has exceeded its current limits
• the Auxiliary Outputs have exceeded their current limits

7.8 Restrict Arming on TLM Failure

S
[3035]: O
[4]
ECTION
PTION
(default = disabled) When enabled, the control panel can prevent arming if
it is unable to access the telephone line.
16 Reference & Installation Manual

Arming and Disarming Options

7
Partition arms & disarms with:
Option [1] =
Partition 1
Option [2] =
Partition 2
Option [3] =
Partition 3
Option [4] =
Partition 4
Option [5] =
Partition 5
Option [6] =
Partition 6
Option [7] =
Partition 7
Option [8] =
Partition 8

7.9 Restrict Arming on Module Troubles

S
[3035]: O
[5]
ECTION
PTION
(default = disabled) When is enabled, the control panel uses the same
Restrict Arming options for the modules connected to the combus.

7.10 Timed Auto-Arming

(default = disabled) The control panel arms the selected partition every day
at the time set (see section 7.10.1). A 60-second Exit Delay (default value)
triggers before the partition arms. It can be cancelled or postponed by
entering a valid access code. If zones are open, the control panel arms the
partition and considers all open zones as temporarily bypassed (except
24hr. zones). The control panel transmits the Auto-Arming report code
programmed in section [3910]. The control panel will transmit the Late to
Close report code programmed in section [3912]. Enable option [1] in the
desired section:
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]
7.10.1 Auto-Arm Timer
Enter the time when the partition should arm in the desired section:
Partition 1: [3101] Partition 3: [3301] Partition 5: [3501] Partition 7: [3701]
Partition 2: [3201] Partition 4: [3401] Partition 6: [3601] Partition 8: [3801]
7.10.2 Postpone Auto-Arming
(default = 000) It is possible to postpone auto-arming for a preset amount of
time by entering a valid user code during the exit delay. The delay is set by
entering a number between 001 and 255 in the appropriate section. That
number represents for how many increments of 15 minutes the arming will
be postponed.
Partition 1: [3120] Partition 3: [3320] Partition 5: [3520] Partition 7: [3720]
Partition 2: [3220] Partition 4: [3420] Partition 6: [3620] Partition 8: [3820]

7.11 No Movement Auto-Arming

(default = disabled) If no movement occurs in a partition for the specified
period, the control panel will automatically arm that partition. The Auto-
Arming Option determines the arming method (see section 7.12). The
control panel will transmit the No Movement report code programmed in
section [3913] upon arming. The control panel will always transmit the Late
to Close report code [3912]. Enable option [2] in the desired section:
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]
7.11.1 No Movement Timer
(default = 000) Select the section corresponding to the desired partition and
program the time without movement necessary before the control panel will
arm and/or send the No Movement report code. If No Movement Auto-
Arming is disabled, the control panel can still send the No Movement report
code. Enter the time period (001 to 255 x 5 minutes, 000 = disabled) when
the partition should arm in the desired section:
Partition 1: [3107] Partition 3: [3307] Partition 5: [3507] Partition 7: [3707]
Partition 2: [3207] Partition 4: [3407] Partition 6: [3607] Partition 8: [3807]
7.11.2 No Movement Schedule
It is possible to program the No-movement arming option for each partition
to follow a schedule. These schedules, which function like access
schedules, will ensure that No-Movement arming only occurs during these
specified periods and not at any moment when there is no movement.