8. Installation
7. Connect Wire of Indoor Unit
(1) Open the panel, remove the screw on the wiring cover and
then take down the cover. (As show in Fig.11)
(2) Make the power connection wire go through the cable-cross
hole at the back of indoor unit and then pull it out from the front
side. (As show in Fig.12)
Cable-cross
hole
Power connection
wire
(3) Remove the wire clip; connect the power connection
wiresignal control wire (only for cooling and heating unit) to the
wiring terminal according to the color; tighten the screw and then
fix the power connection wire with wire clip. (As show in Fig.13)
Note: The wiring connect is for reference only,
please refer to the actual one.
(4) Put wiring cover back and then tighten the screw.
(5) Close the panel.
Note:
(1) All wires of indoor unit and outdoor unit should be connected
by a professional.
(2) If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the wire by
yourself.
(3) For the air conditioner with plug, the plug should be
reachable after finishing installation.
(4) For the air conditioner without plug, an air switch must be
installed in the line. The air switch should be all-pole parting
and the contact parting distance should be more than 3mm.
8. Bind up Pipe
(1) Bind up the connection pipe, power cord and drain hose with
the band. (As show in Fig.14)
(2) Reserve a certain length of drain hose and power cord for
installation when binding them. When binding to a certain degree,
separate the indoor power and then separate the drain hose. (As
show in Fig.15)
(3) Bind them evenly.
(4) The liquid pipe and gas pipe should be bound separately at
the end.
40
Screw
Panel
Wiring cover
Fig.11
Fig.12
N(1)
2
3
green
white
black
red
(yellow-green)
(brown)
(blue)
Outdoor unit connection
Fig.13
Indoor unit
Connection pipe
Indoor power cord
Note:
(1) The power cord and control wire can't be crossed or
winding.
(2) The drain hose should be bound at the bottom.
9. Hang the Indoor Unit
(1) Put the bound pipes in the wall pipe and then make them pass
through the wall hole.
(2) Hang the indoor unit on the wall-mounting frame.
(3) Stuff the gap between pipes and wall hole with sealing gum.
(4) Fix the wall pipe. (As show in Fig.16)
(5) Check if the indoor unit is installed firmly and closed to the
wall. (As show in Fig.17)
Outdoor
Indoor
Wall pipe
Sealing gum
Fig.16
Note:
Do not bend the drain hose too excessively in order to prevent
blocking.

8.6 Installation of Outdoor Unit

1. Fix the Support of Outdoor Unit(Select it according to the
actual installation situation)
(1) Select installation location according to the house structure.
(2) Fix the support of outdoor unit on the selected location with
expansion screws.
Note:
(1) Take sufficient protective measures when installing the
outdoor unit.
(2) Make sure the support can withstand at least four times the
unit weight.
(3) The outdoor unit should be installed at least 3cm above the
floor in order to install drain joint.(As show in Fig.18)
Service Manual
Indoor and
outdoor power cord
Gas
pipe
Liquid
pipe
Band
Drain hose
Fig.14
Drain hose
Band
Fig.15
Upper hook
Lower hook of
wall-mounting frame
Fig.17