Electrolux Inspiration EWX11831 TC4 Service Manual page 16

Table of Contents

Advertisement

Alarm
Description
E87
Display board microprocessor faulty If this continues, replace the display board
Communication error between main
E91
PCB and display
Communication inconsistency
E92
between main PCB and display
(incompatible versions)
E93
Appliance configuration error
Incorrect configuration of washing
E94
cycle
Inconsistency between programme
E97
selector and cycle configuration
Communication error between main
E98
PCB - Inverter
E9C
Display board configuration error
Display board sensor/touch key
E9E
faulty
Solenoid valve blocked with
EC1
operating flowmeter
Drain filter clogged
EF1
(drain phase too long)
Overdosing of detergent
EF2
(too much foam during drain
phases)
EF3
Aqua control system intervention
Water fill pressure too low, no signal
EF4
from flowmeter and solenoid valve is
open
EF5
Unbalanced load
EF6
Reset
Appliance power supply frequency
EH1
out of limits
EH2
Supply voltage too high
EH3
Supply voltage too low
EH4
0Watt relay malfunction
2013 TS/DT-mdm FCPD-dp
Guide to diagnostics of EWX11831 electronic controls
Possible fault
Wiring faulty; Control/display PCB faulty, Inverter board faulty,
Weight sensor board faulty, Main PCB faulty.
Incorrect control/display PCB
Incorrect PCB (does not correspond to the model).
Main PCB faulty (incorrect configuration data);
Main PCB faulty (incorrect configuration data);
Main PCB faulty (incorrect configuration data).
Incompatibility between main PCB and Inverter
Display board faulty
Display board faulty
Wiring faulty; Solenoid valve faulty/blocked, Main PCB faulty,
Drain filter clogged/dirty.
Drain hose blocked/kinked/too high.
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Water leaks onto base frame; Aqua control system faulty.
Tap closed, water fill pressure too low
Final spin phases skipped.
If it continues, replace the main board.
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Main circuit board faulty.
Cycle stops with door locked
Drain pump continues to operate (5 min.
Warning displayed at the end of cycle. START/RESET
Warning displayed after 5 attempts or
16/71
Machine status/action
Reset
START
No action to be taken
ON/OFF
RESET
----------------
RESET
Cycle blocked
ON/OFF
Cycle blocked
ON/OFF
Cycle blocked
ON/OFF
Cycle blocked
RESET
Cycle blocked
ON/OFF
START
----------------
ON/OFF
RESET
----------------
ON/OFF
RESET
on, then 5 min. off. etc.)
RESET
by the specific LED.
Appliance drain
ON/OFF RESET
----------------
RESET
----------------
START/RESET
No action to be taken
----------------
Wait for nominal
ON/OFF
frequency conditions
Wait for nominal
ON/OFF
voltage conditions.
Wait for nominal
ON/OFF
voltage conditions.
ON/OFF
----------------
RESET
Page