SALUS TRV10RFM - Wireless Radiator Controller Manual

SALUS TRV10RFM - Wireless Radiator Controller Manual

Also See for TRV10RFM:

Advertisement

SALUS TRV10RFM - Wireless Radiator Controller Manual

Contents of the box

Icons used in this manual:
danger Safety

information Important info

Contents:
Box Contents
Introduction
Product Compliance and Safety Information
Installation
User Interface
Status/LED indication
Installers notes
Warranty

System Overview

To achieve the best control from the unit and thermostat, we recommend they are used with the SALUS system receiver configured to RX1. The system receiver will turn the boiler on or off when requested by the thermostat. See your boiler receiver manual for more information about the RX1 configuration.

information The unit is modulating, which means it opens or closes partially or 100% depending on the relationship between the actual room temperature and the required room temperature measured by the VS10/20RF.

System Overview

information Up to 6 units can be connected to a VS10RF/VS20RF

Checking the compatibility of your heating system

If you can not see any thread on the valve and it looks like this picture, you may be able to use the RA adapter supplied. TRV10 fits 30x1,5 mm thread.
Checking the compatibility of your heating system Part 1

Our RA adapter also fits this valve.
Once fitted the RA adapter should look like this.

Checking the compatibility of your heating system Part 2

Preparing to Pair the Unit

  1. Press and hold the button on the Universal Gateway for five seconds. This puts the Universal Gateway in pairing mode. See your Universal Gateway manual for more information.
  2. Ensure the wireless thermostat is powered up and ready for pairing. See your thermostat manual for more information.
  3. If you are using the optional RX10RF wireless boiler receiver configured for remote boiler switching, ensure this has been powered up and the red LED has gone from flashing to steady. See your boiler receiver manual for more information.

Pairing the Unit

Press and hold the pairing button for 10 seconds. You can pair up to 6 units with one thermostat. Pair the units room by room.

You have paired the unit to the thermostat when the unit LED goes off. Once paired, the unit operates in automatic mode and receives room temperatures from the thermostat.

Product Compliance & Safety Information

INTRODUCTION

The TRV10RFM is a battery-powered, mini-size thermostatic radiator valve (TRV) controller using ZigBee wireless communication. Simply replace the existing, passive head on the standard radiator valve with the TRV10RFM (referred to from now on as the unit). Use the unit with the VS10RF or VS20RF series of wireless thermostats and a Universal Gateway.

Product Compliance

information This product is CE compliant and meets the following EC Directives: Electro-Magnetic Compatibility directive 2014/30/EU; 2014/53/EU and 2011/65/EU.

Safety Information

dangerUse in accordance with the regulations. The unit is to be used for the control of room temperature inside the house.

Installation

dangerThis accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.

Checking the compatibility of your heating system

The SALUS TRV10RFM is compatible with the majority of thermostatic radiator valves. Before fitting, please check your valve is suitable for use with the SALUS TRV.

  1. Remove the TRV head
    Checking the compatibility of your heating system

Note: If all the measurements are as stated on this page then the TRV will fit directly to your valve. Also if your valve is not suitable please consider changing your existing valves, contact your installer.

  1. Measure the thread diameter (must measure 30mm)
  2. Measure the pin length of the valve when it is in the open position. (must measure between 13-16mm)

Installing the Unit

  1. Remove the battery door on the side of the unit
  2. Insert the batteries, ensuring correct orientation
  3. The LED on the unit flashes green then flashes red before changing to solid red. When it is solid red, place the unit over the radiator valve using the mounting ring if needed:
    Installing the Unit
  4. Screw the units nut (finger tight) to the radiator valve and check that the LED is solid red.
  5. Press any button on the unit to adapt it to the radiator valve. Once all adaptation noise and LED activity has stopped, the unit is ready to pair with your wireless thermostat.
  6. The unit is now ready for pairing to the SALUS thermostat. You may now start the pairing process.

Leaving the Network

Once paired to a thermostat, press and hold the pairing button on the unit for 10 seconds.

The red LED come on together for one second.

Note: After you have deleted the unit from the wireless network, you must reinstall the TRV see Installing the unit.

Using the Unit

Using the Unit

Auto Lock Function
Auto lock function is disabled until you have gone through the pairing process. After pairing, the TRV will auto lock after 5 minute if no buttons have been pressed.

Unlocking the Buttons
To unlock the buttons, press the pairing and close buttons together for 3 seconds.

Opening the Valve Manually
Press the open button for 3 seconds. The LED flashes green once and the valve opens.

Closing the Valve Manually
Press the close button for 3 seconds. The LED flashes red once and the valve closes.

Entering Fail Safe Mode
In fail safe mode, the unit opens the valve 25% for water flow to maintain room temperature.

To enter fail safe mode, press and hold the open and close buttons together for 3 seconds.

To exit fail safe mode, press the:

  • Pairing button to put the unit in automatic mode
  • Open button for 3 seconds to open the valve
  • Close button for 3 seconds to close the valve

Restoring Factory Default Settings
Press the pairing, open, and close buttons together for 10 seconds.

Protecting against Frost
When you have manually closed the valve, the unit automatically enables frost protection. Frost protection starts only when the temperature in the room drops below the frost temperature setpoint. The unit does all this automatically when connected to a thermostat and you don't have to do anything.

Detecting Open Windows
The unit checks the rate of temperature drop in the room in which it is located. If the drop is rapid, it assumes a window in the room has been opened. This only works if the unit is paired to the thermostat and is in automatic mode and the battery in the unit is not low. The unit does all this automatically when connected to a thermostat and you don't have to do anything. It works between 0 and 40⁰C.

Protecting against Lime Scale
Do not leave a valve open for a long time because this could cause a build up of lime scale. The unit has a lime-scale protection feature to prevent against this. The valve motor automatically starts once a week if no valve movement has been detected within a 14day period. Lime-scale protection will continue to operate in automatic, manual open, and manual close modes and you don't have to do anything.

Auto Adaptation
Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed it will auto adapt to the valve.

Button Usage

To do this... Press the...
Leave the network Pairing button for 10 seconds (when unit already in network)
Pair with thermostat Pairing button for 10 seconds
Put unit in automatic mode Short press Pairing button
Fully open the valve Open button for 3 seconds
Fully close the valve Close button for 3 seconds
Restore factory default settings Open, pairing, and close buttons together for 3 seconds
Lock and unlock the buttons Pairing and close buttons together for 3 seconds

Manual Override

To remove the unit from auto mode, follow the steps below. If the buttons are locked, unlock them by pressing the pairing and close buttons together for 3 seconds.
Manual Override - Step 1
Press for 3 seconds to manually open.
LED flashes green once and then goes out. To check status refer to table above.

Manual Override - Step 2
Press for 3 seconds to manually close.
LED flashes red once and then goes out.

To check status refer to refer to table above.


Short press to return to Auto mode. Red LED will flash once to confirm that the unit is in AUTO.

LED Indications

When... The LEDs... Valve
Power switched on or after reset Software Version indication A sequence of red and green LEDs flashing displayed indicates the software version
Unit adapting to valve Red flashes then goes steady. Green flashes (or red flasheson failure to adapt). Green steady. Green and red flash (or red flashes on failure to adapt)
Unit has not joined network
or has not paired to thermostat
Auto mode Green and red flash alternately after short press on open or close button 25% open
Manual open Green flashes twice after short press on open or close button 100% open
Manual close Red flashes twice after short press on open or close button 0% open
Unit paired to thermostat and in auto mode No LED
Leaving network Red and green on together for one second
Identifying the network Green flashes for up to 10 minutes
Wireless link to thermostat lost
Auto mode Green and red flash alternately after short press on open or close button
Manual open Green flashes twice after short press on open or close button 100% open
Manual close Red flashes twice after short press on open or close button 0% open
Normal operation


Auto mode Green flashes once after short press on open or close button 1 to 100% open
Auto mode Red flashes once after short press on open or close button 0% open
Manual open Green flashes twice after short press on open or close button 100% open
Manual close Red flashes twice after short press on open or close button 0% open
Window open mode active Green and red flash twice every 10 seconds 100% open
Battery low Red flashes three times every 10 seconds (less if the battery is low) 25% open
Error installing Green and red flash alternately

Technical Detail

Model TRV10RFM
Type Hydraulic Radiator Valve
DC Motor
M30 x 1.5
Input Three push buttons:
  • Manual open/status indication
  • Manual close/status indication
  • Pairing
LED Indicator Bi-Colour, Red/Green
Valve Adaptation Automatic
Power Source 2x AA Batteries
Battery Life 14 Months (low battery indication)
Control Method Modulating
Communication 2.4GHz ZigBee wireless
Operating Temperature 0 to 45ºC
Storage Temperature -20 to 60ºC
Operating Humidity 5 to 95"RH
Protection IP30
Size (mm) H 88.6, W 51

Warranty

SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.

SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.

SALES: T: +44 (0) 1226 323961
E: sales@salus-tech.com

TECHNICAL: T: +44 (0) 1226 323961
E: tech@salus-tech.com

www.salus-controls.com

SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change specification, design and materials of products listed in this brochure without prior notice.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download SALUS TRV10RFM - Wireless Radiator Controller Manual

Advertisement

Need Assistance?

Do you have a question about the TRV10RFM that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents