Advertisement
Icons used in this manual:
Safety
Important info
Contents:
Box Contents
Introduction
Product Compliance and Safety Information
Installation
User Interface
Status/LED indication
Installers notes
Warranty
To achieve the best control from the unit and thermostat, we recommend they are used with the SALUS system receiver configured to RX1. The system receiver will turn the boiler on or off when requested by the thermostat. See your boiler receiver manual for more information about the RX1 configuration.
The unit is modulating, which means it opens or closes partially or 100% depending on the relationship between the actual room temperature and the required room temperature measured by the VS10/20RF.
Up to 6 units can be connected to a VS10RF/VS20RF
Checking the compatibility of your heating system
If you can not see any thread on the valve and it looks like this picture, you may be able to use the RA adapter supplied. TRV10 fits 30x1,5 mm thread.
Our RA adapter also fits this valve.
Once fitted the RA adapter should look like this.
Press and hold the pairing button for 10 seconds. You can pair up to 6 units with one thermostat. Pair the units room by room.
You have paired the unit to the thermostat when the unit LED goes off. Once paired, the unit operates in automatic mode and receives room temperatures from the thermostat.
The TRV10RFM is a battery-powered, mini-size thermostatic radiator valve (TRV) controller using ZigBee wireless communication. Simply replace the existing, passive head on the standard radiator valve with the TRV10RFM (referred to from now on as the unit). Use the unit with the VS10RF or VS20RF series of wireless thermostats and a Universal Gateway.
This product is CE compliant and meets the following EC Directives: Electro-Magnetic Compatibility directive 2014/30/EU; 2014/53/EU and 2011/65/EU.
Use in accordance with the regulations. The unit is to be used for the control of room temperature inside the house.
This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
The SALUS TRV10RFM is compatible with the majority of thermostatic radiator valves. Before fitting, please check your valve is suitable for use with the SALUS TRV.
Note: If all the measurements are as stated on this page then the TRV will fit directly to your valve. Also if your valve is not suitable please consider changing your existing valves, contact your installer.
Measure the pin length of the valve when it is in the open position. (must measure between 13-16mm)
Once paired to a thermostat, press and hold the pairing button on the unit for 10 seconds.
The red LED come on together for one second.
Note: After you have deleted the unit from the wireless network, you must reinstall the TRV see Installing the unit.
Auto Lock Function
Auto lock function is disabled until you have gone through the pairing process. After pairing, the TRV will auto lock after 5 minute if no buttons have been pressed.
Unlocking the Buttons
To unlock the buttons, press the pairing and close buttons together for 3 seconds.
Opening the Valve Manually
Press the open button for 3 seconds. The LED flashes green once and the valve opens.
Closing the Valve Manually
Press the close button for 3 seconds. The LED flashes red once and the valve closes.
Entering Fail Safe Mode
In fail safe mode, the unit opens the valve 25% for water flow to maintain room temperature.
To enter fail safe mode, press and hold the open and close buttons together for 3 seconds.
To exit fail safe mode, press the:
Restoring Factory Default Settings
Press the pairing, open, and close buttons together for 10 seconds.
Protecting against Frost
When you have manually closed the valve, the unit automatically enables frost protection. Frost protection starts only when the temperature in the room drops below the frost temperature setpoint. The unit does all this automatically when connected to a thermostat and you don't have to do anything.
Detecting Open Windows
The unit checks the rate of temperature drop in the room in which it is located. If the drop is rapid, it assumes a window in the room has been opened. This only works if the unit is paired to the thermostat and is in automatic mode and the battery in the unit is not low. The unit does all this automatically when connected to a thermostat and you don't have to do anything. It works between 0 and 40⁰C.
Protecting against Lime Scale
Do not leave a valve open for a long time because this could cause a build up of lime scale. The unit has a lime-scale protection feature to prevent against this. The valve motor automatically starts once a week if no valve movement has been detected within a 14day period. Lime-scale protection will continue to operate in automatic, manual open, and manual close modes and you don't have to do anything.
Auto Adaptation
Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed it will auto adapt to the valve.
To do this... | Press the... |
Leave the network | Pairing button for 10 seconds (when unit already in network) |
Pair with thermostat | Pairing button for 10 seconds |
Put unit in automatic mode | Short press Pairing button |
Fully open the valve | Open button for 3 seconds |
Fully close the valve | Close button for 3 seconds |
Restore factory default settings | Open, pairing, and close buttons together for 3 seconds |
Lock and unlock the buttons | Pairing and close buttons together for 3 seconds |
To remove the unit from auto mode, follow the steps below. If the buttons are locked, unlock them by pressing the pairing and close buttons together for 3 seconds.
Press for 3 seconds to manually open.
LED flashes green once and then goes out. To check status refer to table above.
Press for 3 seconds to manually close.
LED flashes red once and then goes out.
To check status refer to refer to table above.
Short press to return to Auto mode. Red LED will flash once to confirm that the unit is in AUTO.
When... | The LEDs... | Valve | |
Power switched on or after reset | Software Version indication | A sequence of red and green LEDs flashing displayed indicates the software version | |
Unit adapting to valve | Red flashes then goes steady. Green flashes (or red flasheson failure to adapt). Green steady. Green and red flash (or red flashes on failure to adapt) | ||
Unit has not joined network or has not paired to thermostat | Auto mode | Green and red flash alternately after short press on open or close button | 25% open |
Manual open | Green flashes twice after short press on open or close button | 100% open | |
Manual close | Red flashes twice after short press on open or close button | 0% open | |
Unit paired to thermostat and in auto mode | No LED | ||
Leaving network | Red and green on together for one second | ||
Identifying the network | Green flashes for up to 10 minutes | ||
Wireless link to thermostat lost | Auto mode | Green and red flash alternately after short press on open or close button | |
Manual open | Green flashes twice after short press on open or close button | 100% open | |
Manual close | Red flashes twice after short press on open or close button | 0% open | |
Normal operation | Auto mode | Green flashes once after short press on open or close button | 1 to 100% open |
Auto mode | Red flashes once after short press on open or close button | 0% open | |
Manual open | Green flashes twice after short press on open or close button | 100% open | |
Manual close | Red flashes twice after short press on open or close button | 0% open | |
Window open mode active | Green and red flash twice every 10 seconds | 100% open | |
Battery low | Red flashes three times every 10 seconds (less if the battery is low) | 25% open | |
Error installing | Green and red flash alternately |
Model | TRV10RFM |
Type | Hydraulic Radiator Valve DC Motor M30 x 1.5 |
Input | Three push buttons:
|
LED Indicator | Bi-Colour, Red/Green |
Valve Adaptation | Automatic |
Power Source | 2x AA Batteries |
Battery Life | 14 Months (low battery indication) |
Control Method | Modulating |
Communication | 2.4GHz ZigBee wireless |
Operating Temperature | 0 to 45ºC |
Storage Temperature | -20 to 60ºC |
Operating Humidity | 5 to 95"RH |
Protection | IP30 |
Size (mm) | H 88.6, W 51 |
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 (0) 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 (0) 1226 323961
E: tech@salus-tech.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change specification, design and materials of products listed in this brochure without prior notice.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download SALUS TRV10RFM - Wireless Radiator Controller Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the TRV10RFM that isn't answered in the manual? Leave your question here.