5.3 Electromagnetic compatibility

5.3
Electromagnetic compatibility
The HMI device satisfies, among other things, the requirements of the EMC guidelines of the
European domestic market.
EMC-compatible installation of the HMI device
The EMC-compliant installation of the HMI device and the application of interference-proof
cable is the basis for interference-free operation.
Observed the following manuals in addition to these operating instructions:
• Designing interference-free controllers
(https://support.industry.siemens.com/cs/ww/en/view/59193566)
• Industrial Ethernet / PROFINET - Passive network components
(https://support.industry.siemens.com/cs/ww/en/view/84922825)
• PROFIBUS networks (https://support.industry.siemens.com/cs/ww/en/view/1971286)
Pulse-shaped disturbance
The following table shows the electromagnetic compatibility of modules with regard to pulse-
shaped interference. The precondition for electromagnetic compatibility is that the HMI
device meets the specifications and guidelines for electrical installation.
Pulse-shaped interference
Electrostatic discharge
in accordance with
IEC 61000-4-2
Bursts
(high-speed transient
interferences)
in accordance with
IEC 61000-4-4
High-energy single pulse
(surge) in accordance with
IEC 61000-4-5
1
You can find the Function Manual "Designing interference-free controllers" for download on
the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566).
32
1
The following applies to Comfort V1/V1.1 devices: External protective circuit required, see Function
Manual "Designing interference-free controllers", section 7 "Lightning protection and overvoltage
protection"
Tested with
Air discharge: 8 KV
Contact discharge: 6 kV (front)
Contact discharge: 4 kV (rear)
2 kV supply cable
1 kV signal line, < 30 m
2 kV signal line, > 30 m
Asymmetrical coupling (line to ground):
1 kV supply cable, DC voltage
1 kV signal line/data cable, > 30 m
Symmetrical coupling (line to line):
0.5 kV power cable, DC voltage
1 kV signal line, > 30 m
Compact Operating Instructions, 08/2022, A5E33472156-AP
Performance level
equivalence
3
2
3
4
2
2
3
Comfort Panels INOX, ITC INOX