7. BLOWING
7.1
Push the large end of the flexible hose into the blow
connection in the top section.
7.2
Ensure the power switch is turned off and plug in the
power supply.
7.3
Switch on the power (position ‘I’).
7.4
The unit will now blow through the vacuum hose and can be used to clear obstructions within the pipe.
WARNING! If after a few seconds the hose is still blocked turn of the unit and clear the hose manually.
p
p
8. USING DUST FREE TOOLS
8.1
Ensure that the cleaner switch (A) and the dust free tool
switch (B) on the vacuum cleaner are both in the OFF position.
8.2
Connect the flexible hose to the front inlet on the cleaner.
8.3
Connect the other end of the hose to the dust outlet on the dust free tool using the rubber
adaptor supplied. Part no. DFS/AK10 (See above), the tapered end of which can be cut back to
suit the tool outlet diameter.
8.4
Ensure that the switch on the dust free tool is in the OFF position, then plug the tool into
the power outlet (C) on the vacuum cleaner.
8.5
Keep the dust free tool in the OFF position whilst you move both switches (A) & (B) on the cleaner into the ON position.
8.6
The cleaner will start automatically when you operate the switch on the dust free tool.
8.7
When you switch the dust free tool OFF the cleaner will continue to run for ten seconds then shut down automatically.
8.8
When you have finished using the tool, move both switches (A) & (B) on the cleaner to the OFF position before unplugging the tool.
NOTE: If no tool is plugged in, but the tool switch (B) on the cleaner is in the ON position the cleaner will not start. Move the tool switch to
the OFF position and operate the cleaner as normal using the cleaner ON/OFF switch (A).
9. MAINTENANCE
9.1.1
GENERAL MAINTENANCE.
9.1.2
Ensure the machine is unplugged from the power supply.
9.1.3
Disconnect the hose from the container.
9.1.4
Undo the clasps and remove motor head from the container.
9.1.5
Clear out any dirt or debris from the container and hose.
9.1.6
Clean the foam filter by washing it in a mild soapy solution.
9.1.7
Check that the telescopic suction tube operates smoothly, and check the power cable to make sure it has not received any damage.
9.2.1
CARTRIDGE FILTER MAINTENANCE. (Handle the filter carefully when cleaning or installing.)
9.2.2
Carefully remove the optional cartridge filter (A) and inspect it for damage. A filter that has small holes or tears in it will not perform
efficiently and should be replaced.
9.2.3
To clean a dry filter, tap it inside a waste bin. (B)
9.2.4
Do not use the filter if it becomes wet as the filter will clog quickly and be very difficult to clean. (The cartridge filter is designed for dry
vacuuming only.) Should the filter be inadvertently wetted it should be rinsed from the inside (B) and allowed to air dry for 24 hours.
9.2.5
To fit a new/cleaned filter slide it over the filter basket (C) and push it fully home (D)
10. TROUBLESHOOTING
Cleaner will not operate.
Dust comes from the motor cover.
Reduced efficiency and increased
motor speed/vibration.
9.
CONSUMABLES
MODEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PC200SDAUTO.V2 . . . . . . . . . . . . . . . . . . . . . . . . PC300SDAUTO.V2
Cartridge Filter (Must be used for dry vacuuming) . . . . . . .Part No. PC200CF . . . . . . . . . . . . . . . . . . . . . . . . . Part No. PC200CF
Foam Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Part No. PC200FF10 . . . . . . . . . . . . . . . . . . . . . . . Part No. PC200FF10
Dust Bags (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . .Part No. PC200PB5 . . . . . . . . . . . . . . . . . . . . . . . . Part No. PC300PB5
IMPORTANT! IF THE MACHINE IS USED WITHOUT A CARTRIDGE FILTER FITTED THE MOTOR WILL BURN OUT EVENTUALLY AND
YOUR GUARANTEE WILL BE INVALIDATED. ALWAYS KEEP A SPARE CARTRIDGE FILTER HANDY.
INDUSTRIAL VACUUM CLEANERS WITH
AUTO START/STOP
Models: PC200SDAUTO.V2 & PC300SDAUTO.V2
98/37/EC Machinery Directive
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
93/68/EEC CE Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
No power supply.
Faulty power cable, switch or motor.
Container full of liquid.
Dust free tool switch in ‘ON’ position
Cartridge filter missing or damaged.
Container full / filter clogged
Nozzle, hose or container inlet blocked.
Declaration of Conformity
The construction files for these products are held by the Manufacturer and may be inspected,
by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Check supply.
Check and repair or replace faulty item.
Empty container.
Switch dust free tool switch ‘OFF’
Fit or replace cartridge filter.
Empty container / clean or replace filter.
Check nozzle, hose and container inlet for blockage.
We, the sole importer into the UK, declare that the products listed here are
in conformity with the following standards and directives.
14th December 2005
01284 757500
01284 703534
PC200SDAUTO.V2 & PC300SDAUTO.V2 - 1 - 14/12/05
For Jack Sealey Ltd.
Sole importer into the UK
of Sealey Power Products
www.sealey.co.uk
Web
sales@sealey.co.uk
email

Advertisement

loading

This manual is also suitable for:

Pc300sdauto.v2