DTD no. 24-6160
5
Touch Current Measurement
Note
On machines with a ground connection, touch current leakage measurements
should be carried out on all accessible conductive parts that are not connected
to ground.
Warning!
Touch current measurement should only be carried out after the ground
connection of the machine under test has been checked and found to be
satisfactory! Dangerous voltages may exist on defective machines as well as on
accessible conductive parts that are not connected to ground!
Note
Touch current measurement should be carried out on the following accessible
conductive parts:
Stainless-steel door.
01.10.2014, US_am
Descriptive Technical Documentation
This information should not be duplicated or passed on without Miele approval. All rights reserved.
A-5