Download Print this page

Terminal Strip Connections - A.O. Smith ADMP - 115 Technical Specifications

Atmospheric commercial water heater

Advertisement

ADMP / ADM / ADMR
Electrical diagram ADM

TERMINAL STRIP CONNECTIONS

Earth
N
Neutral
L1
Phase input of controller
L2
Phase input of flue gas
thermostat
L3
Phase output of flue gas
thermostat
COMPONENTS
A
Two-terminal main switch
B
Flue gas thermostat
C
Indicator LED "Error"
D
Indicator LED "Running"
E
"RESET" button
F
Burner control
G
Control thermostat
H
Frost thermostat
J
0/1 switch of controller
K
Safety thermostat
L
High-limit thermostat
M
Extra error sensor
N
Gas control
O
Glow igniter
P
Ionisation rod
CONNECTIONS ON BURNER CONTROL
N1
Neutral
Earth
L'
Phase input of burner control
L"
Phase output to safety circuit and
thermostat circuit
TH
Phase input of thermostat circuit
GV1
Phase output to gas control
MAX Phase input of safety thermostat
LG
Phase output to glow igniter
I
Ionisation signal detection
NO
"Normally open" port of the
extra error sensor
P
Phase input of extra error sensor
NC
"Normally closed" port of the
extra error sensor
F1
Fuse