3.7 TABLE FO USER-SETTABLE PARAMETERS
Parameter
Parameter description
N.
P1
Time of day setting
P5
Minimum central heating temperature setting (°C)
P11
Start of rst daily period of automatic central heating
P12
End of rst daily period of automatic central heating
P13
Start of second daily period of automatic central heating
P14
End of second daily period of automatic central heating
P15
Start of third daily period of automatic heating
P16
End of third daily period of automatic central heating
Start of rst daily period of domestic hot water production
*
P31
End of rst daily period of domestic hot water production
*
P32
Start of second daily period of domestic hot water production
*
P33
End of second daily period of domestic hot water production
*
P34
Start of third daily period of domestic hot water production
*
P35
Fine End of third daily period of domestic hot water production
*
P36
Reset of daily central heating and domestic hot water production programs (factory
P45
settings). Press the - + keys together for about 3 seconds; the number 1 appears
on the display. Con rm by pressing either of the
*
Parameters for program lines P31 to P36 are displayed only if
rameter H91 see section 14) is activated.
3.8 FAULT WARNINGS AND RESETTING THE BOILER
If a fault occurs, a ashing warning code
appears on the display.
The fault warnings appear on the main
display ( gure 1 a) together with the
symbol (Figure 4).
To reset, press the reset
least two seconds.
Fault warnings appear on the secondary
display ( gure 1 b) alternating with the time,
both of them ashing ( gure 4.1). It is not
possible to reset malfunction warnings
which appear on the secondary display
as the cause of the alarm has rst to be
removed.
ISTRUCTIONS PERTAINING TO THE USER
hydroheat.com.au
keys
button for at
Figure 4
Figure 4.1
9
Factory
setting
———-
25
6:00
22:00
0:00
0:00
0:00
0:00
0:00
24:00
0:00
0:00
0:00
0:00
0
Domestic Hot Water
(D.H.W.) program (pa-
910.026.1 - EN (AUS)
Range
0...23:59
25..80
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
00:00...24:00
0...1