1-8. Notes on Service

1-8-1. Power circuit breaker

Excessive current in the internal circuitry, whatever the
cause, will trip the internal circuit breaker, automatically
cutting off the power. After checking that the problem has
been corrected, press the button shown in the figure. The
power should come on again.
CA-701

1-8-2. Notes on replacement of V shoe

It is necessary to attach the V shoe on the main chassis
with precisely position when will attach the CA-701 on the
DVW-700 in absolute contact.
Tighten the three screws sequentially in the figure when
attach the V shoe on the main chassis. When the V shoe is
replaced, check that the specification is met.
RE-123 board

1-9. Tool

Extension board BC-155: J-6421-550-A
Specification: a–b = 0 ± 0.1 mm
a
b
1
3
2
1-8. Notes on Service
1-9. Tool
1-9 (E)