Advertisement

Quick Links

Instructions For Use
Jet Mixer
Filtration. Separation. Solution.
SM
020-17469-00 Instructions For Use Jet Mixer RevD

Advertisement

Table of Contents
loading

Summary of Contents for Pall Jet Mixer

  • Page 1 Instructions For Use Jet Mixer Filtration. Separation. Solution. 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 2: Table Of Contents

    Maintenance and inspection ................. 17 Transport ......................17 Storage ......................... 17 General machine specifications ................18 Materials ....................... 18 Capacity ........................ 18 Noise level ......................18 Operating temperature ..................18 Service ........................18 Warranty ........................19 www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 3: Introduction

    All safety precautions and safety provisions in use in the company must be known and respected. The Jet Mixer is a mixing system that contains of stainless steel jacketed and non-jacketed tanks, with a holder for a magnetic driver and a controller, that are used as biocontainerholder for various sizes of Jet Mixer biocontainers (50L, 200L, 500L and 1000L).
  • Page 4: Assembly And Commissioning

    Required electrical utility: The Telemodul 700827 can be used on a single phase net of 220V. • The Telemodul 700828 can be used on a single phase net of 110V. • www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 5: System Components

    System components Table 1 describes the different components of the Jet Mixer mixing system. Figure 1 - Figure 4 show the main components. Table 1: Jet Mixer system components Component Description Function Stainless steel tank with drain Holder for the disposable mixing...
  • Page 6 Figure 2: Control unit holder Figure 3: Drive unit Figure 4: Control unit www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 7: Control Unit

    Lock the wheel brakes of the tank Open the drive unit holder underneath the bottom plate of the tank by releasing the 2 screws and by pulling the holding plate out. The holding plate will rotate downwards. 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 8 The driver has 4 rubber stoppers at the bottom that fit into the 4 square openings of the holding plate. Insert the driver as far as possible to the back (until the hard stop). Lift up the holding plate with driver Figure 9: Inserted drive unit www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 9 The 2 discs on the side of the holder can be rotated. In this way the drive unit can always be positioned vertical. 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 10 Figure 13: Control unit holder on a jacketed tank Figure 14: Control unit holder on a non-jacketed tank Insert the control unit into the control unit holder. Figure 15: Installed control unit www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 11 Connect the communication cable from the drive unit to the control unit and connect the power cable. Figure 16: Connected power and communication cable Plug the power cable into the mains electricity and switch on the control unit with the ON/OFF button at the back side. 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 12: Operation Of The Control Unit

    RPM will ensure a stable coupling and will prevent decoupling of the magnet. For further functional information of the driver and controller in specific, we refer to the operating manual of the Variomag Mobil200 and Telemodul 80M. www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 13: Installation And Use Of The Mixing Biocontainer

    Confirm that the drain is fully closed by sliding the locking collar up until it clicks, then pulling down firmly on the blue BarbLock®* to close the drain, and sliding the locking collar down again to lock it (Figure 18). 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 14: Filling The Mixing Biocontainer

    Make sure that the clamp on the drain tubing is closed and that the clamps on the filling tubing are open. Connect the filling tube to the liquid supply and start filling. www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 15: Starting The Mixing Cycle

    If fitted, the EZ Drain valve should be opened by pushing the locking collar upwards until it clicks, then pushing up on the blue BarbLock®* to open the drain, and pulling the locking collar down again to lock it (Figure 19). 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 16 Close all clamps and detach the mixing biocontainer from all external connections. Remove the EZ Drain clip (if used) then carefully lift the empty mixing biocontainer out of the tank. Dispose of the mixing biocontainer according to applicable EH&S policies and regulations. www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 17: Cleaning, Maintenance And Inspection Activities

    Before reinstating the system after a longer period of storing, the Instructions and protocols as mentioned in the equipment manuals must be followed again and the system should be visually check on damages. 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 18: General Machine Specifications

    For information about applicable patents, visit www.pall.com/patents *BarbLock® is a registered trademark of Saint-Gobain Corporation. (Pall logo), Pall and PadMixer are trademarks of Pall Corporation. ® indicates a trademark registered in the USA. © Pall Corporation 2015. www.pall.com/biopharm 020-17469-00 Instructions For Use Jet Mixer RevD...
  • Page 19: Warranty

    Pall liability under any warranty is limited solely to replacing, or issuing credit for the Allegro systems that may become defective during the Warranty Period.

Table of Contents