Barco R9841810 Installation Manual page 11

Universal lamp replacement kit for slm *8/*10 and r9+/r12+ projectors
Hide thumbs Also See for R9841810:
Table of Contents

Advertisement

Image 4-4
Optical alignments scews
Necessary tools
Allen Key 3mm
nut driver 10mm
How to adjust
Optical alignment of the lamp to the z-axis, follow the next procedure:
1. Put a lightmeter in the center of the screen.
2. Enter the 'RANDOM ACCESS ADJUSTMENT MODE', select consecutively 'Picture Tuning' and 'Colour Temperature'. Finally
set Colour Temperature on 'PROJECTOR WHITE'.
3. Enter the 'INSTALLATION MODE' and select 'Internal Patterns'. Finally set Internal patterns on 'PURITY'.
4. Enter the 'SERVICE MODE' and select 'Add-Ins'. Finally set CLO on 'INACTIVE'.
5. Loosen the lock nut (A), securing the adjustable screw (B) for the optical Z-axis adjustment.
Image 4-5
Optical alignment Z-axis
6. Carefully adjust the adjustable screw (B), using an Allen key of 3mm, for maximum light fall on the screen.
7. Lock the adjustable screw by fastening the lock nut (A).
8. Cancel the above modified projector settings (Step 2 to 4).
R5976544 UNIVERSAL LAMP REPLACEMENT KIT 04/01/2005
Y
Z
4. Inserting the new lamp Unit
X
Factory Preadjusted
B
A
9

Advertisement

Table of Contents
loading

Table of Contents