Before you call for service
Problem
Error Codes 1,3,4,5
on Control
Error Codes 6,7,8 on
Control
If "Err" in display
Advanced troubleshooting for service
AUTOMATIC ELECTRONIC
DIAGNOSTICS
This water softener has a
self-diagnostic function for the
electrical system (except into
power and/or water meter).
The water softener monitors
electronic components and
circuits for correct operation. If a malfunction
occurs, an error code appears in the display.
While an error code appears in the display, all
buttons are inoperable except the MODE/SET
button. MODE/SET remains operational so the
service person can perform the Manual Advanced
Diagnostics, see below, to further isolate the
problem.
Procedure for removing error code from
display:
1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 8 minutes. The error code will return if the
problem was not corrected.
MANUAL INITIATED ELECTRONIC
DIAGNOSTICS
Use the following procedures to advance the
water softener through the regeneration cycles to
check operation.
Possible Cause
Wiring may have worked
loose in the control
Issue with Water Shutoff
valve
Electrical problem with
system
Call for Service
Figure 17
What to do
• Unplug external power supply.
• Remove control cover, release clips on side.
• Check for loose/incorrect wiring connections to electronic board
or switch. Reconnect as required.
• Reassemble control cover.
• Plug in Transformer.
• Wait 8 minutes for Error Code to reappear.
• If error Code reappears, call for service.
• Unplug external power supply.
• Replace the water Shutoff valve.
• Check for loose/incorrect wiring connections to electronic board.
Reconnect as required.
• Reassemble control cover.
• Plug in Transformer.
– When the Error 6,7 or 8 is displayed, press and hold the
Recharge button for 5 seconds.
• Wait 2 minutes for Error Code to reappear.
• If error Code reappears, call for service.
• Call for service.
Lift off the Salt Hole Cover, remove the top cover
by unlocking the tabs in the back and rocking
forward, to observe cam and switch operation
during valve rotation.
1. Press and hold MODE/SET for 3 seconds until
the Set low salt alarm display appears, next
press the MODE/SET button two addition times
until "000" shows in the display, then release,
see Figure 18.
2. The 3 digits indicated water meter operation
as follows: If you don't get a reading on the
display, with faucet open, pull the sensor from
the valve outlet port. Pass a small magnet back
and forth in front of the sensor. You should get
a reading in the display. If you get a reading,
shut off water supply, unhook the in and out
plumbing and check the turbine for binding.
Position
switch
Valve
outlet
31
Motor
Sensor
housing
Turbine
Turbine
support and
shaft