Various Control; Auto Restart; Manual Auto Operation - Fujitsu ASUH09LPAS Service Manual

Wall mounted type
Hide thumbs Also See for ASUH09LPAS:
Table of Contents

Advertisement

7. Various control

7-1. Auto restart

When the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time (set by wireless remote controller)
Airflow direction setting
Swing
ECONOMY operation
Remote control setting
WLAN indicator lamp setting

7-2. MANUAL AUTO operation

When the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
When MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode
Fan mode
Timer mode
Setting temperature
Horizontal louver setting
SWING
ECONOMY
Human sensor
7-1. Auto restart
Operation contents memorized when the power is interrupted
Continuous (no timer setting available)
- (04-25) -
Auto changeover
AUTO
75.2°F (24°C)
Standard
Off
Off
Off