Fault
E:61-03 will light up
alternately. Water is
not drained.
E:92-40 will light up
alternately.
All LEDs lit up or
flashing.
Cause and troubleshooting
Not an appliance fault. Wastewater pump is blocked
or the cover of the wastewater pump is loose.
Clean the wastewater pump.
1.
→ "Clean wastewater pump", Page 51
Secure the cover of the wastewater pump so it
2.
clicks into position.
→ "Clean wastewater pump", Page 51
Filters are soiled or blocked.
Clean the filters.
→ "Cleaning filters", Page 42
Electronics have detected a fault.
Press the main switch button for approx.
1.
4 seconds.
The appliance is reset and restarted.
If the problem occurs again:
2.
Switch off the appliance.
Pull out the mains plug or switch off the fuse in
the fuse box.
Wait at least 2 minutes.
Switch on the fuse in the fuse box or insert the
mains plug.
Switch the appliance on.
If the problem occurs again:
3.
Contact customer service.
→ "Customer Service", Page 52
Troubleshooting en