Aprilaire S86W MUPR Safety & Installation Instructions page 12

Wi-fi thermostat with iaq
Hide thumbs Also See for S86W MUPR:
Table of Contents

Advertisement

TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Extends fan operation 90 seconds
Extended Fan –
after heat call ends NOTE: Only
Heat
available with electric heat
Extended Fan –
Extends fan operation 90 seconds
Cool
after cool call ends
Enable or disable Auto Changeover
Auto Changeover
mode
DeadBand
Auto Changeover mode deadband
Auto Changeover
Minimum time between heating and
Time
cooling calls
Field adjustment of controlling
Temp Sensor Offset
temperature sensors
Internal RH sensor Increases or
RH Sensor Offset
decreases displayed RH%
Equipment
Minimum on time for heating and
Minimum On Time
cooling
22
Factory default setting (bold)
and setting range
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
3°F (1.5°C)
2 to 9°F (1 to 45°C)
4 Minutes
1 to 5 Minutes
0°F (0°C)
-4 to 4°F (-2 to +2°C)
0
-5 to 5
2 Minutes
1 to 5 Minutes
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Heating Minimum
Minimum off time for heating
Off Time
Compressor
Minimum off time for compressor
Minimum Off Time
protection
Outdoor
Enable or disable high balance point
Temperature High
(Available if an ODT is installed)
Balance Point
If outside temperature is above the
High Balance Point
high balance point the aux heat
Temperature
operation is not allowed (Available if
high balance point is enabled)
Outdoor
Enable or disable low balance point
Temperature Low
(Available if an ODT is installed)
Balance Point
If outside temperature is below the
Low Balance Point
low balance point the compressor
Temperature
operation is not allowed (Available if
low balance point is enabled)
Factory default setting (bold)
and setting range
2 Minutes
1 to 5 Minutes
5 Minutes
1 to 5 Minutes
Enabled
Disabled
65°F (14.5°C)
0 to 80°F (-18 to 22°C)
Enabled
Disabled
20°F (-8°C)
0 to 60°F (-18 to 12°C)
23