Chapter 3. Operation
VIEW SIG BITS (View Signalling Bits)
Use VIEW SIG BITS to view the status of the RX and TX
signalling bits in the DS-1 stream. See Figure 3-4. If you
are operating in a SLC96 mode,
may be displayed.
1/0
This means that the signalling bit is toggling in each suc-
cessive frame for that port.
Figure 3-4. View Signalling Bits Display
SLC96 STATUS (Single and UVG Status)
SLC96 Status is used to view the signalling states on a
per- channel basis related to the Channel (Network
Interface) and the Customer (2W Ports). The states are
shown in lexical representation to aid in determining
system status without monitoring and translating the
signalling bits (VIEW SIG BITS). SLC96 STATUS is only
available when SINGLE or UVG modes of operation are
selected. See Figure 3-5.
Figure 3-5. SLC96 Status Display
61202300L1-1
FXS+ Quad Voice Option Module User Manual
3-5