Shipping And Packing List; General; Unit Support - Lennox Humiditrol L Series Installation Instructions Manual

Table of Contents

Advertisement

Shipping and Packing List

Package 1 of 1 contains:
1− Assembled unit
IMPORTANT
This
field−provided
and
(17M50).
Check unit for shipping damage. Consult last carrier
immediately if damage is found.

General

These instructions are intended as a general guide and
do not supersede national or local codes in any way.
Authorities having jurisdiction should be consulted before
installation.
In addition to standard heating and cooling, Humiditrolt
units provide a dehumidifying mode of operation. Refer to
Reheat Operation section.
See figure 1 for unit dimensions, figure 2 for parts
arrangement and figure 3 for service clearances.
LGA/LCA036−072 SERVICE CLEARANCES
É É É É É É É É É
É É É É É É É É É
É É É É É É É É É
É É É É
É É É É É É É É É
É É É É
É É É É
EVAP.
36"
É É É É
BLOWER
É É É É
É É É É
É É É É É É É É É
É É É É É É É É É
É É É É É É É É É
É É É É É É É É É
FIGURE 3
IMPORTANT
The Clean Air Act of 1990 bans the intentional vent
ing of refrigerant (CFC's and HCFC's) as of July 1,
1992. Approved methods of recovery, recycling or
reclaiming must be followed. Fines and/or incar
ceration may be levied for non−compliance.
unit
requires
a
specific
installed
humidity
sensor
36"
É É É É É
É É É É É
É É É É É
36"
HEAT
COND.
SEC
FAN
É É É É É
TION
É É É É É
COMP.
É É É É É
36"
Danger of sharp metallic edges. Can cause injury.
Take care when servicing unit to avoid accidental
contact with sharp edges.
Electric shock hazard and danger of
explosion. Can cause injury, death or
product or property damage. Turn off
gas and electrical power to unit before
performing
servicing operations on the unit.
Follow lighting instructions attached
to unit when putting unit back into
operation
maintenance.

Unit Support

A−Roof Mounting with LARMF − Downflow Discharge
Application
1− The LARMF roof mounting frame must be installed,
flashed and sealed in accordance with the
instructions provided with the frame.
2− The LARMF roof mounting frame should be square
and level to 1/16" per linear foot (5mm per linear
meter) in any direction.
3− Duct must be attached to the roof mounting frame
and not to the unit: Supply and return plenums must
be installed before setting the unit.
B−Roof Mounting With Installer's Frame − Downflow
Applications
Many types of roof frames can be used to mount the unit,
depending upon different roof structures. Items to keep in
mind when using the building frame or supports are:
1− The base is fully enclosed and insulated, so an
enclosed frame is not required.
2− The frames or supports must be constructed with
non−combustible materials and should be square and
level to 1/16" per linear foot (5mm per linear meter) in
any direction.
3− Frame or supports must be high enough to prevent
any
form
Recommended frame height is 14" (356mm).
4− Duct must be attached to the roof mounting frame
and not to the unit: Supply and return plenums must
be installed before setting the unit.
Page 3
CAUTION
WARNING
any
maintenance
and
after
service
of
moisture
from
entering
or
or
unit.