CABINET DISASSEMBLY INSTRUCTIONS

1. Disassembly Flowchart
This flowchart indicates the disassembly steps to gain
access to item(s) to be serviced. When reassembling,
follow the steps in reverse order. Bend, route, and
dress the cables as they were originally.
[1] Top Case
[2] Front Assembly
[3] VCR Chassis Unit
[4] Function CBA
[5] Deck Assembly
[6] Main CBA
2. Disassembly Method
ID/
LOC.
PART
Fig.
No.
No.
[1]
Top Case
1
Front
[2]
2
Assembly
VCR
[3]
Chassis
3
Unit
Function
[4]
4
CBA
Deck
[5]
4,5
Assembly
[6]
Main CBA 4,5
(1)
(2)
(3)
All manuals and user guides at all-guides.com
REMOVAL
REMOVE/*UNHOOK/
UNLOCK/RELEASE/
Note
UNPLUG/DESOLDER
3(S-1)
*3(L-1),*4(L-2)
*(L-3), 5(S-2)
Desolder
3(S-3), Desolder
----------
(4)
(1): Identification (location) No. of parts in the figures
(2): Name of the part
(3): Figure Number for reference
(4): Identification of parts to be removed, unhooked,
unlocked, released, unplugged, unclamped, or
desoldered.
P=Spring, L=Locking Tab, S=Screw,
CN=Connector
*=Unhook, Unlock, Release, Unplug, or Desolder
e.g. 2(S-2) = two Screws (S-2),
2(L-2) = two Locking Tabs (L-2)
(5): Refer to "Reference Notes."
Reference Notes
CAUTION: Locking Tabs (L-1) and (L-2) are fragile.
Be careful not to break them.
1. Release Locking Tab (L-3) and remove five Screws
(S-2). Then slowly lift the VCR Chassis Unit (Deck
Assembly, Function CBA and Main CBA) up.
2. When reassembling, solder wire jumpers as shown
in Fig. D4.
3. Before installing the Deck Assembly, be sure to
place the pin of LD-SW on Main CBA as shown in
Fig. D5. Then, install the Deck Assembly while
aligning the hole of Cam Gear with the pin of LD-
SW, the shaft of Cam Gear with the hole of LD-SW
as shown in Fig. D5.
-
-
1
-
[1] Top Case
2,3
-
(5)
1-6-1
(S-1)
Fig. D1
HB300DC