Safety Devices - Fujitsu ASTG09KMTC Design & Technical Manual

Wall mounted type
Table of Contents

Advertisement

11. Safety devices

Type of
protection
Circuit
Current fuse (Main PCB)
protection
Fan motor
Terminal protection program
protection
Terminal protection program
(Discharge temp.)
Compressor
protection
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 59 -
Model
AOTG09KMTC
250 V, 20 A
250 V, 5 A
250 V, 3.15 A
100±15°C
Fan motor stop
95±10°C
Fan motor restart
110°C
Compressor stop
After 7 minutes
Compressor restart
-15°C
Compressor stop
-10°C
Compressor restart
AOTG12KMTC
11. Safety devices