Electrical Characteristics - Fujitsu ASTG09KMTC Design & Technical Manual

Wall mounted type
Table of Contents

Advertisement

10. Electrical characteristics

Model name
Voltage
Power supply
Frequency
1
Max operating current*
Starting current
Circuit breaker current
Power cable
2
Wiring spec. *
Connection
3
cable*
*1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
V
Hz
A
A
A
2
mm
Cross-
2
mm
sectional area
Limited wiring
m
length
- 58 -
AOTG09KMTC
240 ~
50
7.5
3.5
10
1.5
1.5
21
AOTG12KMTC
9.0
4.2
10. Electrical characteristics