(5) Paying special attention to the cautions below, secure the NC500 of the right channel and the heat
sink in two locations with screws.
Caution : (5-1) The heat sink and chassis holes must be properly aligned.
(5-2) The NC500 connecter must be completely connected. (connector must not be unplugged)
(5) Rch
(5-1)
x2
(6) Pull the AMP block forward, then remove the connector that connects the NC500 and SPK PCB.
(7) Secure the NC500 and the heat sink with screws in 4 locations.
※ Any silicone grease that protrudes from the area around the NC500 must be wiped off.
Additionally, there must not be any silicone grease on any other surrounding components. (wipe
off if there is any)
(8) Install the AMP block on the SPK circuit board connector.
(6)
(9) Screw the AMP block into the chassis (8 locations total, left and right).
(10) Assemble the "SHIELD PLATE AMP", "1. AUDIO PCB", "3. FCBS1 PCB" and "4. TRANS ASSY".
(9)
x3
(5-2)
NG
OK
x2
(7)
(8)
(10)
(10)
(10)
(10)

13. REAR PANEL ASSY

Proceeding : TOP COVER → SIDE PANEL → AUDIO PCB → PHONO ASSY →
→ REAR PANEL ASSY
(1) Remove the screws. Remove the connector. Cut the wire clamps.
x2
↑Shooting direction: A↑
41
N8851
x1
CUT x4
x2
x3
NC500 PCB