Carrier WeatherMaker 48TC Series Service And Maintenance Instructions page 73

Single package rooftop unit with gas heat/electric cooling and puron (r-410a) refrigerant
Hide thumbs Also See for WeatherMaker 48TC Series:
Table of Contents

Advertisement

Position:
Example:
Unit Heat Type
48 - Gas Heat Packaged Rooftop
®
Model Series - WeatherMaker
TC - Standard Efficiency
Heat Options
D = Low Gas Heat
E = Medium Gas Heat
F = High Gas Heat
S = Low Heat w/ Stainless Steel Exchanger
R = Medium Heat w/ Stainless Steel Exchanger
T = High Heat w/ Stainless Steel Exchanger
Refrig. Systems Options
D = Two stage cooling model with Round Tube/Plate Fin
Coils
E = Two stage cooling models with Humidi-MiZer
Cooling Tons (Horizontal Air Flow)
18 = 15 tons
21 = 17.5 tons
25 = 20 tons
29 = 25 tons
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
2
G = SA Smoke Detector and CO
2
H = RA + SA Smoke Detector and CO
J = Condensate Overflow Switch
K = Condensate Overflow Switch and RA Smoke Detectors
L = Condensate Overflow Switch and RA and SA Smoke Detectors
Indoor Fan Options & Air Flow Configuration
5 = Standard Static/Horizontal Supply, Return Air Flow
(except 29 size models)
6 = Medium Static/Horizontal Supply, Return Air Flow
(Standard on 29 size models)
7 = High Static/Horizontal Supply, Return Air Flow
F = Medium Static, High Efficiency Motor/Horizontal Supply, Return Air Flow
G = High Static, High Efficiency Motor/Horizontal Supply, Return Air Flow
NOTE:
Not all possible options are displayed. See the current
48TC Horizontal 15 to 25 Ton Price Pages for more details.
APPENDIX A — MODEL NUMBER NOMENCLATURE
1
2
3
4
5
6
7
8
4
8
T
C
D
D
2
5
®
System
2
Fig. B — Model Number Nomenclature (Horizontal Units)
9 10 11 12 13 14 15 16 17 18
A
5
A
5
-
0
A
0
A
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels + Unpowered Convenience Outlet
5 = Hinged Panels + Powered Convenience Outlet
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2-Position Damper
U = Temp Ultra Low Leak Economizer w/ Barometric Relief
W = Enthalpy Ultra Low Leak Economizer w/ Barometric Relief
Base Unit Controls
0 = Electro-mechanical Controls. Can be used with W7212
EconoMi$er IV (Non-Fault Detection and Diagnostic)
1 = PremierLink™ Controller
2 = RTU Open Multi-Protocol Controller
6 = Electro-mechanical w/ 2-Speed Fan and W7220
Economizer Controller. Can be used with W7220
EconoMi$er X (with Fault Detection and Diagnostic)
Design Revision
- = Factory Design Revision
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
Coil Options – RTPF (Outdoor – Indoor – Hail Guard)
A = Al/Cu – Al/Cu
B = Precoat Al/Cu – Al/Cu
C = E-coat Al/Cu – Al/Cu
D = E-coat Al/Cu – E-coat Al/Cu
E = Cu/Cu – Al/Cu
F = Cu/Cu – Cu/Cu
M = Al/Cu – Al/Cu – Louvered Hail Guard
N = Precoat Al/Cu – Al/Cu – Louvered Hail Guard
P = E-coat Al/Cu – Al/Cu – Louvered Hail Guard
Q = E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guard
R = Cu/Cu – Al/Cu – Louvered Hail Guard
S = Cu/Cu – Cu/Cu – Louvered Hail Guard
73
0
Packaging
0 = Standard
Electrical Options
A = Non-USA models - No (SAV) included
C = Non-Fused Disconnect
G = Standard USA models - (SAV) included
J = 2 Speed Fan Controller (VFD) and
Non-Fused Disconnect