¢ Model: AOHG14KMCC
Check point 1. Check the terminal connection.
Check the following terminal connections of the compressor. (Loosening or incorrect wiring.)
R (U): Red
S (V): White
C (W): Black
Check the following terminal connections of the Main PCB. (Loosening or incorrect wiring.)
W400 (U): Red
W401 (V): White
W402 (W): Black
Check point 2. Check the winding resistance.
Check the winding resistance of each terminal.
Resistance value: 1.975 ±7 % Ω at 25 °C
C(W)
→ If the resistance value is 0 Ω or infinite, replace the compressor.
4-2. Inverter compressor
S (V)
Main PCB
R (U)
Main PCB
(U)
(V)
Red
Compressor
RED
R(U)
WHITE
S(V)
BLACK
- (03-42) -
C (W)
(W)
Black
White