The AMP-700 contact uses a 2-wire connection for power and to
communicate with the control panel. This, in combination with low power
devices, simplifies wiring and reduces device count for fast and efficient
installations.
The AMP-700 has a magnetic contact and an internal tamper switch so as
to monitor both the alarm and tamper states.
Specifications
Current Rating .................................................................................... 0.8mA
Operating Environment ....................................... 0°C - 49°C (32°F - 120°F)
.................................................................... 5% - 95% RH, non-condensing
Size (H x W x D) .................................. 27 x 85 x 19mm / 1
Control Panel Compatibility
PC4010/4020 v3.x
PC5010/PC5015 v2.x with PC5100 interface module
Connection Diagram
Run the connection wires through the wiring holes on the back of the unit.
Mounting
To mount the unit, remove the plastic cover and secure the unit to the
desired location with the screws provided. Replace the cover.
Mount the magnet next to the reed switch, as shown in the diagram
above.
Device Enrollment
The serial number located on the back of the device must be enrolled into the
alarm control panel via Installer's Programming ([ ] [8] [Installer's Code]).
This procedure is outlined for the PC4010/4020 in the control panel
Installation Manual and for the Power panels in the PC5100 Installation
Manual.
WARNING: Connect only DSC Addressable Series devices to the
addressable loop connections. Connection of ANY other type of device will
impair operation. Any devices other than Addressable Series devices
which require power to operate must be powered separately.