Lennox SIGNATURE SL280UHV Installation Instructions Manual page 47

Hide thumbs Also See for SIGNATURE SL280UHV:
Table of Contents

Advertisement

BLOWER DATA
SL280UH135V60D BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR, RETURN AIR FROM BOTH SIDES OR RETURN AIR FROM BOTTOM AND ONE SIDE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1025
Factory Default
965
875
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1030
Factory Default
960
845
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch
1
Settings.
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 500 cfm.
Lennox Harmony III™ Zone Control Applications - Minimum blower speed is 426 cfm.
First Stage Heating Speed - cfm
1875
1785
1695
1605
1515
1425
1330
1240
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1120
1325
1015
1180
930
1060
First Stage Heating Speed - cfm
1850
1760
1670
1580
1490
1400
1310
1225
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1105
1305
1005
1175
925
1050
HEATING
Second Stage Heating Speed - cfm
COOLING
Second Stage Cooling Speed - cfm
High
Low
Medium-Low
2
1650
1500
1490
1420
1350
1225
HEATING
Second Stage Heating Speed - cfm
COOLING
Second Stage Cooling Speed - cfm
High
Low
Medium-Low
2
1635
1525
1480
1355
1340
1240
Page 47
2065
1965
1865
1765
1665
1565
1465
1365
Medium-High
1600
1840
1510
1700
1320
1505
2035
1935
1835
1740
1640
1540
1445
1345
Medium-High
1600
1840
1435
1635
1315
1520
High
2
2235
2110
1840
High
2
2255
2035
1850

Advertisement

Table of Contents
loading

This manual is also suitable for:

Signature sl280v

Table of Contents