PERFORMANCE DATA - 3.5 TON

CONDENSER-ONLY DATA (OUTDOOR UNIT)
SATURATED SUCTION
@ COMPRESSOR
MODEL
T (°F)
35
40
TC3B4222S
45
50
55
Notes:
1. For Outdoor Unit (Condenser) performance only. Data does not include the effects of air handler power or heat.
2. Performance based on 15°F subcooling and 15°F superheat at the Outdoor Unit base valves.
a. Increase capacity by 1% for each 2°F increase in subcooling.
b. Decrease capacity by 1% for each 2°F decrease in subcooling.
3. Maximum recommended condensing temperature is 140°F.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
ID CFM
AIR TEMP.
ENTERING
ID DB (°F)
OUTDOOR UNIT (°F)
ID WB (°F)
55
65
75
85
95
105
115
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Green shaded cells are ACCA (TVA) conditions.
Blue shaded cells are AHRI conditions.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Johnson Controls Ducted Systems
55 °F
P (PSIG)
MBH
KW
107
38.0
2.48
119
41.9
2.47
130
46.0
2.47
143
50.4
2.47
156
55.1
2.48
TC3B4222S
CF42CXA1
1200
80
80
75
57
62
62
T.C.
37.3
39.9
39.6
S.C.
37.3
31.3
26.8
KW
2.38
2.40
2.40
T.C.
36.7
39.5
39.4
S.C.
36.7
32.3
27.5
KW
2.62
2.64
2.63
T.C.
36.2
39.1
39.1
S.C.
36.2
33.4
28.1
KW
2.86
2.87
2.86
T.C.
35.2
37.3
37.3
S.C.
35.2
32.9
27.7
KW
3.17
3.20
3.19
T.C.
34.2
35.5
35.6
S.C.
34.2
32.5
27.2
KW
3.48
3.53
3.51
T.C.
32.1
32.8
33.0
S.C.
32.1
31.4
26.3
KW
3.86
3.92
3.89
T.C.
30.0
30.1
30.3
S.C.
30.0
30.1
25.4
KW
4.24
4.31
4.27
Outdoor Ambient Temperature
65 °F
75 °F
MBH
KW
MBH
KW
MBH
36.3
2.71
34.5
2.97
32.6
39.9
2.70
38.0
2.96
35.9
43.8
2.70
41.7
2.96
39.5
48.1
2.70
45.7
2.95
43.2
52.5
2.70
49.9
2.96
47.3
1400
80
80
80
80
67
72
57
62
41.5
42.0
37.9
40.3
40.0
25.2
19.2
37.9
32.4
27.5
2.41
2.43
2.46
2.48
2.48
41.7
43.2
37.6
39.9
39.8
25.9
20.0
37.6
33.7
28.6
2.66
2.66
2.70
2.72
2.71
41.8
44.3
37.3
39.5
39.5
26.7
20.8
37.3
34.9
29.6
2.90
2.90
2.94
2.95
2.95
40.7
43.4
36.4
37.9
37.9
26.9
20.6
36.4
34.8
29.4
3.23
3.23
3.25
3.29
3.27
39.6
42.5
35.6
36.2
36.3
27.1
20.3
35.6
36.2
29.2
3.55
3.57
3.57
3.62
3.59
37.1
40.6
33.5
33.9
33.6
26.4
20.0
33.5
33.9
28.3
3.96
3.99
3.96
4.01
3.97
34.6
38.7
31.4
31.6
31.0
25.6
19.8
31.4
31.6
27.4
4.36
4.41
4.35
4.41
4.36
5581710-CTG-C-0619
85 °F
95 °F
KW
MBH
KW
MBH
3.26
30.7
3.59
28.7
3.25
33.8
3.58
31.6
3.24
37.2
3.57
34.8
3.24
40.8
3.56
38.2
3.24
44.6
3.57
41.9
75
80
80
80
80
62
67
72
57
62
41.8
42.4
38.4
40.7
25.8
19.4
38.4
33.6
2.49
2.51
2.54
2.56
42.0
43.6
38.4
40.3
26.7
20.4
38.4
35.0
2.74
2.75
2.78
2.80
42.2
44.9
38.4
39.9
27.6
21.4
38.4
36.4
2.98
2.99
3.02
3.03
41.1
44.0
37.7
38.5
28.1
21.3
37.7
36.7
3.31
3.32
3.34
3.37
40.0
43.1
36.9
37.0
28.6
21.2
36.9
37.0
3.64
3.65
3.66
3.70
37.6
41.2
34.9
35.1
28.1
21.0
34.9
35.1
4.04
4.07
4.06
4.11
35.2
39.3
32.8
33.2
27.7
20.8
32.8
33.2
4.44
4.49
4.46
4.51
105 °F
115 °F
KW
MBH
KW
3.97
26.5
4.40
3.97
29.3
4.40
3.95
32.3
4.39
3.94
35.5
4.38
3.94
39.0
4.37
1600
75
80
80
62
67
72
40.4
42.0
42.8
28.2
26.5
19.6
2.56
2.57
2.59
40.2
42.3
44.1
29.7
27.5
20.8
2.79
2.82
2.83
40.0
42.6
45.4
31.1
28.6
21.9
3.03
3.06
3.07
38.5
41.5
44.5
31.2
29.3
22.0
3.35
3.39
3.40
37.0
40.4
43.6
31.3
30.1
22.0
3.67
3.72
3.73
34.3
38.1
41.7
30.4
29.9
21.9
4.06
4.12
4.15
31.6
35.7
39.9
31.6
29.7
21.7
4.46
4.53
4.57
105