036-21326-001-C-0202 DESCRIPTION Both the outdoor and indoor units are completely piped and APPLICATION FLEXIBILITY INDOOR wired at the factory and are shipped ready for immediate installation. Only the interconnecting liquid and suction lines, B L O W E R M O T O R control wiring, and the main power wiring are required to L O C A T I O N A I R O U T...
036-21326-001-C-0202 PRODUCT NOMENCLATURE OUTDOOR CONDENSING UNITS AND HEAT PUMPS (UPG BRANDS) H F - 10 C 00 A T A AA 1 A Model Model Number Options Description Product Category H = Air Conditioner Split System E = Split System Heat Pump Product Identifier F = R-22 Standard Efficiency 2-Pipe L = R-22 Standard Efficiency 4-Pipe...
036-21326-001-C-0202 INDOOR SPLIT UPG PRODUCT NOMENCLATURE L F –10 C 00 T A AA 1 A Model Model Number Options Description Product Category L = Air Handling Unit- Cooling F = Air Handling Unit- Heat Pump F = R-22 Standard Efficiency 2-Pipe Product Identifier L = R-22 Standard Efficiency 4-Pipe Nominal Cooling...
036-21326-001-C-0202 FIGURE 4 : VERTICAL ARRANGEMENTS - LL180 AND LL240 FIGURE 5 : HORIZONTAL ARRANGEMENTS - LL180 AND LL240 CAUTION CERTAIN BLOWER POSITIONS ARE NOT RECOMMENDED BECAUSE THE BLOWER MOTOR SHOULD NOT BE MOUNTED UPSIDE DOWN. Unitary Products Group...
036-21326-001-C-0202 All dimensions are in inches. They are subject to change without notice. Certi- fied dimensions will be provided upon request. OUTDOOR UNIT DIMENSIONS Dimensions (In.) Unit 15 Ton 37.5 45.75 110.5 20 Ton 37.5 45.75 128.1 TABLE 8: CONNECTIONS Connection Entry Connection Size 15 Ton...
036-21326-001-C-0202 FIGURE 8 : PIPING AND ELECTRICAL CONNECTION LOCATIONS TABLE 11: PIPING AND ELECTRICAL CONNECTION SIZES SIZE CONNECTION ENTRY SUCTION LINE SYS #1 1-3/8 ID LIQUID LINE SYS. #1 5/8 OD SUCTION LINE SYS. #2 1-3/8 ID LIQUID LINE SYS. #2 5/8 OD POWER WIRING 2”...
036-21326-001-C-0202 TABLE 12: 15 TON CAPACITY TABLE - 85º AND 95ºF 15 Ton Capacity Tables HL180 Matched with LL180 AIR ON EVAPORATOR º OUTDOOR AMBIENT TEMPERATURE (F): W.B. GROSS INPUT GROSS SENSIBLE CAPACITY (MBh) TEMP CAP. POWER (RETURN AIR DRY BULB TEMP.- (F))
036-21326-001-C-0202 TABLE 13: 15 TON CAPACITY TABLE - 105º AND 115ºF 15 Ton Capacity Tables HL180 Matched with LL180 AIR ON EVAPORATOR º OUTDOOR AMBIENT TEMPERATURE (F): W.B. GROSS INPUT GROSS SENSIBLE CAPACITY (MBh) TEMP CAP. POWER (RETURN AIR DRY BULB TEMP.- (F)
036-21326-001-C-0202 TABLE 20: BLOWER DRIVE DATA Drive Data Unit Model Adj. Motor Pulley Fixed Blower pulley Belts Model Number Blower RPM Range Datum Dia. (In.) Bore (In.) Datum Dia. (In.) Bore (In.) Qty. Designation 1LD0436 640-810 4.0-5.0 1-3/16 LL180 1LD0437 800-1000 5.3-6.3 1-1/8...
036-21326-001-C-0202 TABLE 23: INDOOR UNIT WEIGHTS AND CORNER WEIGHTS Shipping Unit Unit Unit Size Position Operating Weight Length Width 15 Ton Indoor Horizontal 89.5 15 Ton Indoor Vertical 89.5 29.5 20 Ton Indoor Horizontal 1115 20 Ton Indoor Vertical 1115 36.5 NOTE: All dimensions in inches.
036-21326-001-C-0202 FIGURE 14 : LL180 SUPPLY AIR PLENUM DIMENSIONS 1. Shipped knocked down for field assembly FIGURE 15 : RETURN AIR GRILLE FOR LL180 DIMENSIONS Unitary Products Group...