Removing The Bulk Dispenser - Whirlpool Maytag MVW6200KW Technical Manual

4.8 cubic foot top load washer
Table of Contents

Advertisement

Available languages

Available languages

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Complete the steps
1-8
from section Removing the Console.
4. Using a 1/4" nut driver remove the ACU screw and slide ACU to the left.
5. Remove 1/4" (6 mm) screw as shown in below figure.
6. Push in on harness retainer and lift to disconnect bulk dispense reed
switch harness.
B
A
A. ACU Screw
34
FOR SERVICE TECHNICIAN'S USE ONLY

Removing the Bulk Dispenser

B. Dispenser Housing
Screw
7. Remove 1/4" (6 mm) screw as shown in below figure.
8. Remove inlet valve assembly by removing two (2) 1/4" (6 mm) screws
and disconnecting valve harness from ACU. Lift the valve assembly and
remove from dispenser housing.
9. Complete the steps
1-8
from section Lifting the Top Panel.
10. Lift the bulk drawer and remove it from housing.
DO NOT REMOVE OR DESTROY

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents